RE 143, RE 143 PLUS, RE 163, RE 163 PLUS
English
6
– High-pressure hose and
spray attachment in good
condition (clean, moving
easily) and correctly
assembled
– For good control of the
machine, the handles
should be clean and dry
with no oil or dirt on them
– Never attempt to modify
the controls or safety
devices in any way
– Set up the machine so that
it cannot slip or tip over.
Only operate the machine
on stable and level ground
Electrical connection
WARNING
Minimize the risk of electrical
shock:
– Voltage and frequency of
the machine (see rating
plate) must match the
voltage and frequency of
the mains supply
– Examine the connecting
cord, power plug and
extension cord for
damage. Do not use the
machine with a damaged
connecting cord, extension
cord or damaged power
plug
– Only connect the machine
to a correctly installed
power socket
– The insulation on the
connecting cord and any
extension cord, the plug
and the coupling must be
fully intact
– Never touch the power
plug, connecting cord and
extension cord and
electrical plug connections
with wet hands
WARNING
Route the connecting cord
and extension cord properly:
– Observe the minimum
cross-section of the
individual cords – see
"Connecting the machine
to the power supply"
– Route and mark the power
cord so that it cannot
become damaged and no
one is endangered –
danger of stumbling!
– Use of unsuitable
extension cords can be
dangerous. Use only
extension cords that are
approved for outdoor use
and are correspondingly
marked and have a
sufficient cross-section
– The connector and
coupling of the extension
cord must be waterproof
and they must not lie in
water
– It is advisable to keep the
plug connection at least
60 mm above the
ground/floor, e.g. by using
a cable drum