7 Assembling the Lawn Mower
Open the side discharge flap (1) and hold it in position.
Swing the chute (2) upwards and lift it away.
Close the side discharge flap (1).
7.5 Fitting and Removing the Blade
7.5.1 Mounting the Blade
Switch off the mower, remove the activation key and
battery.
Stand the mower on end.
Fit washer (1) on the screw (2).
Coat screw (2) with Loctite 243 or Loctite 242.
Fit the blade (3) so that the lugs on the mounting face (4)
engage the recesses in the blade.
Fit the screw (2) together with the washer (1).
Use a piece of wood (4) to block the blade (3).
Tighten down the screw (2) firmly.
7.5.2 Removing the Blade
Switch off the mower, remove the activation key and
battery.
Stand the mower on end.
Use a piece of wood (2) to block the blade (1).
Take out the screw (3).
Remove the washer (4).
Remove the blade (1).