15
Fitting the pleated hose on the elbow –
SR 430 only
N Push narrow hose clamp (1), marks
facing left, onto the elbow (2).
N Push the pleated hose (3) onto the
elbow (2).
N Push the hose clamp (1) onto the
pleated hose (3).
N Line up the marks on the hose
clamp (1) and elbow (2) – as shown.
N Secure the hose clamp (1) with the
screw (4).
Fitting the antistatic system – SR 450
only
N Attach the antistatic wire (1) and
chain (2) to the blower housing with
screw (3).
Fitting the pleated hose on the elbow
SR 450 only
N Push the antistatic wire (1) into the
pleated hose (2).
2
1
0002BA076 KN
3
1
4
3
1
4
0002BA077 KN
2
2
3
1
2
0002BA069 KN