Order number: 900323.001 V1.74 Page 12
© Störk-Tronic 2021 • www.stoerk-tronic.com • Subject to modifications.
Parameter list software .112
J-- Pre-defined parameter sets (password protected)
Para-
meter
Description of function Setting range Default
value
J1
Parameter set 0 ... 5 0
J2
Parameter reset 0 ... 31 (see parameter description) 0
J98
Password for entering the level selection (when PA is displayed)
-99 ... 999 -19
J99
Password of parameter level J--
-99 ... 999 -19
If required, various preset parameter sets can be realized by means of J1.
The parameter J98 is only visible and adjustable via the ST-Bus.
Attention: A change of the parameter set changes all parameter settings!
L-- Networking and display (password protected)
Para-
meter
Description of function Setting range Default
value
L0
Own address ST-bus
(identical to setting Adr)
0: deactivated
1 ... 250
1
L2
Temperature scale 0: °C
1: °F
0
L3
Display mode 0: 3 digits, integers
1: 3 digits, rounded to 0.5
2: 3 digits, 0.1
3: 4 digits, integers
4: 4 digits, rounded to 0.5
5: 4 digits, 0.1
2
L4
Display value See actual values table 0
L6
Software version
L7
Display in standby mode
0: OFF
1: AUS
2: right decimal point
3: right decimal point flashing
1
L40
ST bus release mask for functions 0 .. 255 249
L41
ST bus release mask for functions 0 .. 255 255
L42
Release for a deletion of the counter/runtimes 0: no release
1: Deletion is approved for 10 min
(see A17, N98, T98, J2)
0
L99
Password of parameter level L--
-99 ... 999 -19