Connect to the electricity supply
This appliance must be connected by a
competent person, using fixed wiring
via a
DOUBLE POLE SWITCHED FUSED SPUR
OUTLET
.
We recommend that the appliance is
connected by a qualified electrician,
who is a member of the N.I.C.E.I.C.
and who will comply with the I.E.E.
and local regulations.
WARNING:
T
HIS APPLIANCE MUST BE EARTHED.
The wires in the mains lead are
coloured in accordance with the fol-
lowing code:
Green and Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wires in the mains
lead for the appliance, may not corre-
spond with the coloured markings
identifying the terminals in your spur
box, proceed as follows:
1.The wire which is coloured green
and yellow must be connected to
the terminal marked E (Earth) or
coloured Green.
2.The wire which is coloured blue
must be connected to the terminal
marked N (Neutral, or coloured
Black.
3.The wire which is coloured brown
must be connected to the terminal
marked L (Live), or coloured Red.
INSTALLATION INSTRUCTIONS
FUSE
ON
USE A
3 AMP FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
18