2 Installation
2.1 Generally
The SPEED-COMMANDER frequency inverter makes it possible to regulate the speed of a 3-phased AC
motor in power ranges until 22Kw
This manual must follow the inverter to secure correct installation. Please check the following points:
Is the supplied device in the ordered power range?
Is the inverter damaged under transportation?
Is internal parts or connections plugs damaged or loose?
2.2 Mounting and installation
Safety precautions:
Connection and setup must be carried out by trained personal.
Trained personal must be familiar with all the safety precautions in this manual.
Avoid touching the high voltage parts while powered up and until 5 min after mains power is
removed.
When working with electrical systems always have a second trained person present in case of
emergency. This person could stop the system and give first aid.
The motor terminal might contain high voltage even when motor not running.
The inverter might start unwanted after power up (depends on the parameter setting).
Connection and setup must be carried out in order of the electricity regulations.
Mounting description:
The inverter must be mounted vertically to ensure that the heat sink functions correct and air can flow
freely through.
When mounting inside a box ensure that there are at least 80mm for SC-750/5 to SC3-2200/5 and
100mm for SC3-4000/5 to SC3-22000/5 of free space over and under the inverter.
In some cases it might be necessary to make calculations on the heat caused by the heat loss in the
inverter to ensure long lifetime.
Avoid strong vibrations.
The surrounding conditions of the inverter have influence on the lifetime and functionality of the
device.
Following demands must be kept:
Ambient temperature 0º C to +40º C
Humidity less than 90% (non condensation)
Protection against noise, metal particles, humidity, corrosion and explosive gasses.
Max. Altitude 1000m above sea