Stryker L9000 - Introduction; Service Options; Required Skills, Tools, and Components; Reference Documents

Stryker L9000
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Introduction
This
manual
is
intended
to
be
used
as
a
service
guide
for
Stryker
repair
technicians
in
the
installation,
maintenance,
and
repair
of
the
Stryker
L9000
Light
Source.
It is
meant
to
be
used
in
conjunction
with
the
L9000
Light
Source
User
Manual
(1000-401-120)
and
does
not
replace
existing
documentation.
Service
Options
Factory
Service
Due
to
the
complexity
of
the
L9000
Light
Source,
Stryker
recommends
that
any
malfunctioning
system
be
returned
to
Stryker
Endoscopy
for
repair
or
replacement,
where
specialized
equipment
and
technicians
are
available
to
perform
repairs
while
maintaining
full
product
quality
and
safety.
If
service
is
needed
either
during
or
after
the
warranty
period:
1.
Contact
Stryker
Endoscopy
at
1-800-624-4422,
or
contact
your
local
Stryker
Endoscopy
sales
representative.
2.
Package
all
the
components
carefully
in
the
original
shipping
container,
if
possible.
3.
Ship
the
L9000
Light
Source,
prepaid
and
insured,
to:
Stryker
Endoscopy
Customer
Service
Attention:
Repair
Department
5900
Optical
Court
San
Jose,
California
95138
You
may
request
a
loaner
unit
during
the
repair
period.
On-Site
Service
Stryker
Endoscopy
accepts
responsibility
for
the
effects
on
safety,
reliability,
and
performance
of
the
equipment
only
if
readjustments,
modifications,
and
repairs
have
been
carried
out
exclusively
by
a
person
specifically
authorized
by
Stryker
Endoscopy
to
do
so.
On-site
repair
should
be
carried
out
only
by
qualified
technicians
with
the
proper
test
equipment
listed
in
this
manual,
so
that
the
safety
of
operators
and
patients
is
not
compromised.
In
no
event
shall
Stryker
Endoscopy
be
liable
for
incidental
or
consequential
damages
in
connection
with
or
arising
from
the
performance
or
use
of
its
products
after
unauthorized
modification
or
repair.
Required
Skills,
Tools,
and
Components
The
repair
procedures
described
in
this
manual
require
a
basic
set
of
skills,
tools,
and
replacement
components.
Skills
Stryker
recommends
diagnostic
and
repair
procedures
be
performed
by
authorized,
qualified
technicians
with
training
or
experience
in
the
following:
«
Basic
electronics
technigues
«
Vectorscope
operation
+
Bio-Tek
Safety
Analyzer
«
Multimeter
operation
operation
*
Oscilloscope
operation
Tools
Most
of
the
procedures
described
in
this
manual
can
be
performed
using
a
basic
tool
kit
that
includes
the
items
listed
below.
‘Basic
tools
Advanced
tools
»
Phillips
screwdriver
»
Multimeter
»
Allen
wrench
set
¢
Oscilloscope
。
Flathead
screwdriver
(20
Mhz
or
higher)
+
8”
adjustable
wrench
・
NTSC/Pal
Vectorscope
»
Bio-Tek
Model
601
PRO
Safety
Analyzer
or
equivalent
current
leakage
tester
»
Needlenose
pliers
»
Color
video
monitor
»
Glass
fuse
puller
Components
Certain
replacement
components
are for
in-house
use
only
and
will
not
be
available
to
any
non-Stryker
entity.
Before
any
parts
are
purchased,
an
Indemnification
Letter
must
be
signed
and
submitted
to
Stryker
Endoscopy,
available
from
Customer
Service
at
1-800-624-4422.
Stryker
reserves
the
right
to
incorporate
improvements
to
the
L9000
without
notice
and
will
inform
customers
of
any
significant
upgrades.
All
updated
parts
will
be
fully
interchangeable
with
older
versions
and
will
offer
at
least
the
same
level
of
quality
and
performance.
For
up-to-date
information
on
upgrades
to
the
product
or
to
this
manual,
contact
your
Stryker
representative.
Reference
Documents
None
of
the
in-house
Manufacturing
Assembly
Procedures
(MAPs),
Quality
Inspection
Procedures
(QIPs),
specialty
tools,
jigs,
or
fixtures
listed
in
this
manual
are
available
for
purchase.