EasyManua.ls Logo

Studer D21m - Page 47

Studer D21m
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D21m System
D21m Modules 6-11Date printed: 04.12.08
Input / output impedance 110
Input sensitivity min. 0.2 V
Output level (into 110 ) 3.3 V
SFC range 22...108 kHz
Current consumption (3.3 V) 1.949.422: 0.2 A; ..423: 0.4 A; ..424: 0.6 A
(5 V) 0.65 A
Operating temperature 0...40° C
Input SFC*
Enabled
Bypassed
*
1.949.423 and 1.949.424 onl
y
**
1.949.424 only (see Note 1)
Ch 1
Ch 2
Ch 3
Ch 4
Ch 5
Ch 6
Ch 7
Ch 8
Output Word Length**
24 Bit 20 Bit
18 Bit 16 Bit
Output Sampling Rate**
Ch 4
Ch 3
Ch 8
Ch 7
Ch 6
Ch 5
Ch 2
Ch 1
Ch 5...8
Ch 1...4
Ch 5...8
96 k Ext.
Output SFC**
Bypassed
Enabled
Ch 1...4
48 k 44.1 k
LEDs: LOCK 1...8 These green LEDs are on if a valid AES/EBU signal is available at the
inputs.
Jumpers: Output Word Length (1.949.424 only) Used to set the resolution (output word length) for outputs
1...8.
Please note that for a word length reduction the output SFCs must be set to
Enabled; if so, the output word length is always 21 bit maximum. Whenever
an SFC is enabled, the three least signi cant bits (LSB) are set to digital zero.
This results in the speci ed dynamic range of 120 dB.
Input SFC (1.949.423 and 1.949.424 only) Enabling or bypassing of the SFCs for indi-
vidual AES/EBU input channels.
Output Sampling frequency (1.949.424 only) The output sampling frequency may be set for the AES/
EBU output channel groups 1...4 and 5...8; selection from 44.1 kHz, 48 kHz,
96 kHz, or synchronized by the signal at the AES EXT SYNC IN connector
(see “Note” above).
If no valid signal is provided at the AES EXT SYNC IN connector but Ext.
is selected, the output sampling frequency will be set to the system clock.
Outputs set to Ext. can therefore be used in a very exible way: Connect no
external sync signal, if not necessary, so that the output will be clocked with
the internal system clock. As soon as an external sync signal is provided to
the AES EXT SYNC IN connector, the output will be clocked with the ext.
sync signal.
Output SFC / WL Reduction (1.949.424 only) Enabling/bypassing of the output SFCs, separate for the
AES/EBU output channel groups 1...4 and 5...8. Please note that for word
length reduction the output SFCs must be set to Enabled.

Other manuals for Studer D21m