Wine Storage 71
subzero.com/specs
Planning Information
ELECTRICAL REQUIREMENTS
The electrical supply should be located within the shaded
area shown in the illustration for your specific model.
For model 315W, the electrical supply can be located
anywhere on the back wall of the opening. Follow the
National Electrical Code and local codes and ordinances
when installing the receptacle. A separate circuit, servicing
only this appliance, is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
If you will be connecting the unit to a home security
system, you must allow a minimum of 36"
(914) of the
system’s wiring to be routed in the electrical area desig-
nated for your model.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type