Undercounter Refrigeration 87
subzero.com/specs
Opening Width A
UC-24R, UC-24BG, UC-24C(I) and UC-24RO 24" (610)
UC-15I(P) and UC-15I(P)O 15
1
/4" (387)
24" (610)
OPENING
DEPTH
A
OPENING WIDTH
24" (610)
OPENING DEPTH
34
1
/2" (876)
OPENING
HEIGHT
TOP VIEW
FRONT VIEWSIDE VIEW
Opening Dimensions
UNDERCOUNTER MODELS
Planning Information
ELECTRICAL REQUIREMENTS
For ice machine models, it is recommended that electrical
supply be placed in an adjacent cabinet. For all other
undercounter models, locate the electrical supply within
the shaded area shown in the illustration below. Follow
the National Electrical Code and local codes and ordi-
nances when installing the receptacle. A separate circuit,
servicing only this appliance, is required.
IMPORTANT NOTE: Models UC-24RO and UC-15I(P)O are
designed and safe for use in outdoor applications. When
installed outdoors, a ground fault circuit interrupter (GFCI)
is required to reduce the risk of electrical shock. A GFCI is
not recommended for use with other undercounter models
and may cause interruption of operation.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
FRONT VIEW
15
1
/2"
(394)
3" (76)
2" (51)
LEFT SIDE
OF OPENING
Location of electrical supply.