Troubleshoong Guide
PROBLEM POSSIBLE CAUSES & SOLUTIONS
The appliance does not work Ensure proper connecon.
Check if the circuit-breaker is tripped or if the fuse is blown.
Verify the power socket by connecng another electrical
appliance.
The control dial is set to ‘0’.
The appliance is not cold enough Adjust the temperature seng.
In high ambient temperatures, consider seng the fridge to a
colder temperature.
Limit frequent door openings.
Ensure the door is fully closed and the seal is posioned
correctly.
Allow sucient space around the fridge for proper
venlaon.
If ice is present conduct a manual defrost.
The appliance operates
connuously
Ensure ambient room temperature is within the operang
range. Reduce the number of items inside.
Minimise door openings.
Ensure the door is completely closed - conrm the proper
posioning of the door seal.
Check/adjust the temperature control seng.
Ensure sucient venlaon space.
The light doesnt work Check the appliance is connected to a power supply.
The circuit-breaker is tripped, or a fuse is blown.
The LED lighng may need replacing.
Check that the light switch is not at the "OFF" posion.
V1 9