Section 6
NOISE CONTROL
38
2. ANNUAL AIR FILTER(S) AND A IR INLET SYSTEM INSPECTION
In addition to the instructions in the Maintenance section of the Operator’s Manual, the air filter(s) and entire
air inlet system should be inspected at least annually, to make s ure all parts are securely mounted, that all
joints and connections are tight, that there are no other leaks in the system, and that the filter element(s) are
intact. DO NOT operate compressor with defective air inlet system. Remove and replace defective parts by
ordering with part numbers indicated in the Pa rts List.
Maintenance
Performed
By
Location
Date
Maintenance
Performed
By
Location
Date
DDDDDDDDDDDDDDDDD
3. ANNUAL ENGINE VIBRATION MOUNT INSPECTION
At least annually inspect engine vibration mounts for security of attachment and to make sure the resilient
parts are intact. DO NOT operate compressor with defective engine mounting system. Remove and replace
defective parts by ordering with part numbers indicated in Parts List.
Maintenance
Performed
By
Location
Date
Maintenance
Performed
By
Location
Date
DDDDDDDDDDDDDDDDD