Failure to follow the instructions
and procedures in this manual or,
misuse of this equipment will
VOID its warranty!
WARRANTY NOTICE
PART NUMBER:
KEEP FOR
FUTURE
REFERENCE
USER MANUAL
©
COPYRIGHT 2014 SULLAIR
The information in this manual is current
as of its publication date, and applies to
compressor serial number:
and all subsequent serial numbers.
02250176-180 R05
201403210000
INDUSTRIAL AIR COMPRESSOR
1800, 2200, 3000, 1800V, 2200V, 3000V
18, 22 & 30KW/25 & 30 & 40HP

Questions and Answers

  • D
    Darren MartinezAug 8, 2025
    Why is my Sullair 2200 not building full discharge pressure?
    • J
      javier63Aug 8, 2025
      If your Sullair Air Compressor isn't building full discharge pressure, consider these potential causes: The air demand might be too great, so check service lines for leaks or open valves. The air filter might be dirty, so inspect the filter indicator and replace the element if needed. A plugged inlet valve bleed orifice could also be the problem, so ensure the control line bleed orifice is not blocked. Additionally, the pressure regulator might be out of adjustment or defective, so adjust it or replace the diaphragm if necessary. Finally, a defective unload solenoid valve could be the issue, so check that it closes when energized, and replace it if defective.
  • D
    Devin SmallAug 19, 2025
    Why won't my Sullair 2200 start?
    • J
      Joanna BaxterAug 19, 2025
      If your Sullair Air Compressor won't start, several factors could be the cause. First, check that the main disconnect switch is closed. Another possible cause is a blown line fuse, which would need to be replaced. Also, the motor starter overload might have tripped; try resetting it, and if the issue continues, inspect the motor starter contacts. Finally, low incoming line voltage could be the culprit, so check the voltage and consult your power company if it's too low.
  • K
    Kristopher FlowersNov 27, 2025
    What to do if my Sullair 2200 shuts down with air demand present?
    • J
      James PerkinsNov 27, 2025
      If your Sullair Air Compressor shuts down while there's still air demand, there are several potential reasons. It could be due to a loss of control voltage; try resetting it, and if the problem continues, ensure the line pressure doesn't exceed the compressor's maximum operating pressure. Low incoming voltage can also cause this issue, so consult your power company. Other possibilities include the separator needing maintenance (check the indicator under full load), a high pressure setting in the WS controller (reset it), a defective unload solenoid valve (repair if defective), or a defective blowdown valve (repair if defective). Restricted cooling air flow (clean the cooler and check ventilation), high ambient temperature (improve ventilation), low fluid level (add fluid), or a malfunction...

Summary

Safety Guidelines

General Safety Guidelines

General safety principles for compressor operation and maintenance.

Personal Protective Equipment (PPE)

Required PPE for operating and maintaining the compressor.

Pressure Release Procedures

Steps to safely release system pressure before service.

Fire and Explosion Prevention

Safety measures to prevent fires and explosions during operation.

Moving Parts Safety

Precautions for avoiding injury from moving components.

Electrical Shock Hazards

Critical safety information to prevent electrical shock.

Lifting and Rigging Safety

Guidelines for safely lifting and moving the compressor unit.

Description of Compressor Systems

Compressor Cooling and Lubrication System

Functional description of the system that cools and lubricates the compressor.

Compressor Discharge System

Explanation of the combination separator/sump tank and its functions.

Control System Functional Description

How the capacity control system regulates air output based on demand.

VSD Control System Functional Description

How the VSD and WS controller manage compressor output based on demand.

Specifications and Diagrams

Wiring Diagram-VSD, Parallel Wye SVX9000

Wiring diagram for VSD compressors using SVX9000 with Parallel Wye.

Wiring Diagram, VSD Series Delta A1000

Electrical wiring diagram for VSD compressors using Delta A1000.

Installation Procedures

Ventilation and Cooling Requirements

Guidelines for ensuring adequate airflow for compressor cooling and operation.

Electrical Preparation and Wiring

Requirements for customer wiring, grounding, and power connections.

Maintenance and Troubleshooting

Troubleshooting Introduction

Guide to identifying and resolving common compressor symptoms and issues.

Sullair 2200 Specifications

General IconGeneral
BrandSullair
Model2200
CategoryAir Compressor
LanguageEnglish