EasyManua.ls Logo

Sullair ES-8-25H User Manual

Sullair ES-8-25H
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ROTARY SCREW
ES-8 Series
15, 20, 25 and 30 HP
OPERATOR’S
MANUAL AND
Part Number 02250117-368
ESullair Corporation
PARTS LIST
AIR COMPRESSOR
11, 15, 18.5 and 22KW
KEEP FOR
FUTURE
REFERENCE
Standard and Basic Models

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sullair ES-8-25H and is the answer not in the manual?

Sullair ES-8-25H Specifications

General IconGeneral
BrandSullair
ModelES-8-25H
CategoryAir Compressor
LanguageEnglish

Summary

Section 1 Safety

1.2 Personal Protective Equipment

Requirements for safety equipment for operators and users.

1.3 Pressure Release

Procedures and precautions for pressure release.

1.4 Fire and Explosion Hazards

Safety precautions related to fire and explosion hazards.

1.5 Moving Parts Safety

Safety measures for avoiding contact with moving parts.

1.6 Hot Surfaces and Sharp Edges

Precautions for hot surfaces and sharp components.

1.7 Toxic and Irritating Substances

Safety guidelines for handling toxic substances.

1.8 Electrical Shock Prevention

Safety procedures to prevent electrical shock.

1.9 Safe Lifting Practices

Safe practices for lifting and moving the compressor.

1.10 Entrapment Prevention

Safety procedures to prevent entrapment within the enclosure.

Section 4 Compressor Systems

4.6 Control System Description

Functional description of the control system phases.

Section 6 Compressor Operation- Supervisor II

6.2 Standard Parameter Setup

How to set up standard operating parameters.

6.4 Operating the Compressor

Procedures for operating the compressor in manual and auto modes.

6.7 Initial Start-Up Procedure

Step-by-step procedure for initial compressor start-up.

Section 8 Maintenance

8.6 Parts Replacement and Adjustment Procedures

Procedures for replacing parts and making adjustments.

Control System Adjustment- Electro-Mechanical

Adjusting the control system for electro-mechanical models.

Section 9 Troubleshooting

9.2 Troubleshooting Guide

Chart of symptoms, probable causes, and remedies.

T1 HI Message Troubleshooting

Troubleshooting high discharge temperature issues.

P1 HI Message Troubleshooting

Troubleshooting high sump pressure issues.

SEP MNTN Message Troubleshooting

Troubleshooting separator maintenance messages.

P1, P2, P3 FAIL Troubleshooting

Troubleshooting transducer failure messages.

Low Discharge Pressure Troubleshooting

Diagnosing and fixing low discharge pressure.

High Line Pressure Troubleshooting

Troubleshooting high line pressure above unload.

Excessive Fluid Consumption Troubleshooting

Diagnosing and fixing excessive fluid loss.

Section 10 Illustrations and Parts List

10.15 Wiring Diagram - Full Voltage Electro-Mechanical

Wiring diagram for full voltage electro-mechanical models.

10.16 Wiring Diagram - Full Voltage Supervisor II

Wiring diagram for full voltage Supervisor II models.

10.17 Wiring Diagram - Wye Delta Electro-Mechanical

Wiring diagram for Wye Delta electro-mechanical models.

10.18 Wiring Diagram - Wye Delta Supervisor II

Wiring diagram for Wye Delta Supervisor II models.

10.19 Wiring Diagram - Wye Delta-European

Wiring diagram for Wye Delta European models.

Related product manuals