SECTION 3 1800-3000 USER MANUAL
33
3.7 AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 25-30H
Main Motor HP Motor Type Weight CFM Cooling Air
25 ODP 1575 LBS/714 KG 2000 CFM
25 TEFC 1621 LBS/735 KG 2000 CFM
30 ODP 1584 LBS/718 KG 2000 CFM
30 TEFC 1651 LBS/749 KG 2000 CFM
NOTES:
1. ALLOW 4.00 FT. [1.25 METERS] MINIMUM CLEARANCE
AROUND MACHINE FOR ACCESS AND FREE CIRCULA-
TION OF AIR.
2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORT-
ING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO
MAINTAIN THE COMPRESSOR FRAME LEVEL IS
REQUIRED. THE COMPRESSOR FRAME MUST BE LEV-
ELED AND SECURED BETWEEN THE FRAME AND THE
FOUNDATION. NO PIPING LOADS MUST BE PERMITTED
AT EXTERNAL CONNECTIONS.
3. ALL DIMENSIONS ARE <$t>1/2” [12.7MM].
4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY
IS SHOWN ON DRAWING.
5. IF DUCTWORK IS TO BE INSTALLED FOR COOLING AIR,
HIGH STATIC FAN MUST BE SELECTED. MAX ALLOWABLE
ADDITIONAL STATIC PRESSURE 0.4 IN H20 WITH HIGH
STATIC FAN.
A1: SPACE REQUIRED TO OPEN DOORS
A2:SPACE REQUIRED TO OPEN STARTER PANEL
A3:CONTROLLER
A4:E-STOP
A5:AIR INLET
A6:EXHAUST AIRE OUT
A7:CONTAINMENT PAN DRAIN
A8:INCOMING CUSTOMER POWER SUPPLY 2.50 DIA. [63.5]
A9:MOISTURE DRAIN CONNECTION 1/4” NPT
A10:AIR OUT CONNECTION 1-1/2” NPT
A11:DRYER AIR INLET
A12:DRYER AIR OUTLET