Failure to follow the instructions
and procedures in this manual or,
misuse of this equipment will
VOID its warranty!
WARRANTY NOTICE
PART NUMBER:
KEEP FOR
FUTURE
REFERENCE
USER MANUAL
©
COPYRIGHT 2014 SULLAIR
The information in this manual is current
as of its publication date, and applies to
compressor serial number:
and all subsequent serial numbers.
02250176-180 R05
201403210000
INDUSTRIAL AIR COMPRESSOR
1800, 2200, 3000, 1800V, 2200V, 3000V
18, 22 & 30KW/25 & 30 & 40HP

Questions and Answers

  • B
    Brian OsborneAug 8, 2025
    Why is my Sullair Air Compressor not building full discharge pressure?
    • M
      Mallory ArnoldAug 9, 2025
      If your Sullair Air Compressor isn't building full discharge pressure, consider these potential causes: The air demand might be too great, so check service lines for leaks or open valves. The air filter might be dirty, so inspect the filter indicator and replace the element if needed. A plugged inlet valve bleed orifice could also be the problem, so ensure the control line bleed orifice is not blocked. Additionally, the pressure regulator might be out of adjustment or defective, so adjust it or replace the diaphragm if necessary. Finally, a defective unload solenoid valve could be the issue, so check that it closes when energized, and replace it if defective.
  • G
    Gabriel MooreAug 18, 2025
    Why won't my Sullair 3000 start?
    • J
      Jessica WhitneyAug 18, 2025
      If your Sullair Air Compressor won't start, several factors could be the cause. First, check that the main disconnect switch is closed. Another possible cause is a blown line fuse, which would need to be replaced. Also, the motor starter overload might have tripped; try resetting it, and if the issue continues, inspect the motor starter contacts. Finally, low incoming line voltage could be the culprit, so check the voltage and consult your power company if it's too low.
  • A
    Anthony HarveyNov 27, 2025
    What to do if my Sullair 3000 Air Compressor shuts down with air demand present?
    • K
      Kim MorrisNov 27, 2025
      If your Sullair Air Compressor shuts down while there's still air demand, there are several potential reasons. It could be due to a loss of control voltage; try resetting it, and if the problem continues, ensure the line pressure doesn't exceed the compressor's maximum operating pressure. Low incoming voltage can also cause this issue, so consult your power company. Other possibilities include the separator needing maintenance (check the indicator under full load), a high pressure setting in the WS controller (reset it), a defective unload solenoid valve (repair if defective), or a defective blowdown valve (repair if defective). Restricted cooling air flow (clean the cooler and check ventilation), high ambient temperature (improve ventilation), low fluid level (add fluid), or a malfunction...

Summary

Sullair User Manual Overview

Section 1: Safety

Personal Protective Equipment (PPE)

Guidelines for required personal protective equipment.

Pressure Release and Fire Prevention

Procedures for pressure release and fire/explosion prevention.

Electrical, Lifting, and Substance Safety

Safety precautions for electrical shock, lifting, toxic substances, and hot surfaces.

VSD and Entrapment Safety Warnings

Specific warnings for VSD operation, entrapment, and general hazards.

Section 2: Description

Variable Speed Drive (VSD) Systems

Description of VSD components and control system functions.

Section 4: Installation

Installation Checks: Rotation and Alignment

Procedures for checking motor/fan rotation and alignment during installation.

Section 5: WS Controller

Section 6: Maintenance

Sullair 3000 Specifications

General IconGeneral
BrandSullair
Model3000
CategoryAir Compressor
LanguageEnglish

Related product manuals