NOTES:
1. ALLOW 4.00 FT. [1.25 METERS] MINIMUM CLEARANCE
AROUND MACHINE FOR ACCESS AND FREE CIRCULA-
TION OF AIR.
2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORT-
ING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO
MAINTAIN THE COMPRESSOR FRAME LEVEL IS
REQUIRED. THE COMPRESSOR FRAME MUST BE LEV-
ELLED AND SECURED BETWEEN THE FRAME AND THE
FOUNDATION. NO PIPING LOADS MUST BE PERMITTED
AT EXTERNAL CONNECTIONS.
3. ALL DIMENSIONS ARE ±1/2" [12.7MM].
4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY
IS SHOWN ON DRAWING.
5. IF DUCTWORK IS TO BE INSTALLED FOR COOLING AIR,
HIGH STATIC FAN MUST BE SELECTED. MAX ALLOWABLE
ADDITIONAL STATIC PRESSURE 0.4 IN H20 WITH HIGH
STATIC FAN.
A1: SPACE REQUIRED TO OPEN DOORS
A2: SPACE REQUIRED TO OPEN STARTER PANEL
A3: CONTROLLER
A4: E-STOP
A5: AIR INLET
A6: EXHAUST AIR OUT
A7: CONTAINMENT PAN DRAIN
A8: INCOMING CUSTOMER POWER SUPPLY
Ø2.72[69.0]
A9: MOISTURE DRAIN CONNECTION 1/4"-18 NPT
A10: AIR OUT CONNECTION 1-1/2" NPT