SECTION 6 1800-3000 USER MANUAL
67
Line Pressure Rises Above Unload
Pressure Set-Point
Leak In Control System Causing
Loss of Pressure Signals
Check for leaks.
Inlet Valve Stuck Open Remove the intake hose and check for inlet
valve operation. Repair Valve (kit available).
Defective Unload Solenoid Valve Check that the valve is open when deener-
gized. Replace if necessary.
Plugged Control Line Strainer Clean strainer (screen and O-ring replace-
ment kit available).
Defective Blowdown Valve Check that separator/sump tank pressure is
exhausted to the atmosphere when the
solenoid valve opens. Repair or replace if
necessary (kit available).
Excessive Compressor Fluid Con-
sumption
Clogged Return Line or Orifice Clean strainer (screen and O-ring
replacement kit available).
Clean orifice.
Separator Element Damaged or Not
Functioning Properly
Change separator.
Leak in the Lubrication System Check all hoses, connections and
components.
Excess Fluid Foaming Drain and change.
Fluid Level Too High Drain and change.
Pressure Relief Valve Opens
Repeatedly
Defective Pressure Relief Valve Replace.
Plugged Separator Check separator differential.
Liquid Water In Compressed Air
Lines
Plugged Strainer in Moisture Drain
Line
Clean and service strainer located in the
line off the bottom of the water separator.
Water Vapor Condensation From
Cooling And Compression Occurs
Naturally
Remove the water vapor from compressed
air prior to distribution through the air sys-
tem. Check operation of aftercooler and
moisture separator. Install a compressed air
dryer sized for the flow and dryness level
required. (Note: Filters may also be
required to remove particulates, liquid oil
aerosols or for oil vapor removal. Change
cartridges as recommended by the filter
manufacturer). Check all drain traps rou-
tinely to insure their proper operation. Main-
tain them regularly.
Defective Drain Solenoid Valve Ensure valve opens and closes as signaled
by the WS Controller.
Inadequate Drain Timer Settings Check WS Controller control drain interval
and drain time, and adjust accordingly. High
humidity conditions require longer drain
times or more frequent openings.