3000PB, 3700B, 4500B, 3000PVB, 3700VB, 4500VB User Manual 3: Specifications
02250216-786 R01
Subject to EAR, ECCN EAR99 and related export control restrictions. 27
3.8 Identification, air-cooled
Machine weights
Model
Main motor
hp Motor type Weight
cfm
cooling air
3000PB 40
ODP 2055 LBS/932 kg 4000
TEFC 2079 LBS/943 kg 4000
3700B 50
ODP 2080 LBS/943 kg 4000
TEFC 2120 LBS/962 kg 4000
4500B 60
ODP 2366 LBS/1073 kg 5500
TEFC 2444 LBS/1109 kg 5500
Drawing notes
1
ALLOW 4.00 FEET [1.25 METERS] MINIMUM CLEARANCE
AROUND MACHINE FOR ACCESS AND FREE CIRCULATION
OF AIR.
2
A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING
THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO
MAINTAIN THE COMPRESSOR FRAME LEVEL IS REQUIRED.
THE COMPRESSOR FRAME MUST BE LEVELLED AND
SECURED BETWEEN THE FRAME AND THE FOUNDATION. NO
PIPING LOADS ARE PERMITTED AT EXTERNAL
CONNECTIONS.
3 ALL DIMENSIONS ARE ± .50" [12.7MM].
4
RECOMMENDED INCOMING CUSTOMER POWER SUPPLY IS
SHOWN ON DRAWING.
5
IF DUCTWORK IS TO BE INSTALLED FOR COOLING AIR, HIGH
STATIC FAN MUST BE SELECTED. MAX ALLOWABLE
ADDITIONAL STATIC PRESSURE 0.75 IN H2O WITH HIGH
STATIC FAN.
6
ALL DIMENSIONS SHOWN IN INCHES WITH MILLIMETER
DIMENSIONS IN PARENTHESES.