4: Installation 3000PB, 3700B, 4500B, 3000PVB, 3700VB, 4500VB User Manual
02250216-786 R01
48 Subject to EAR, ECCN EAR99 and related export control restrictions.
trap. A drain line should be installed on the condensate 
drain.
4.5 Coupling alignment check
No coupling alignment is required.
4.6 Fluid level check
The air compressor is shipped with the proper amount of 
fluid installed. However, it is necessary to check the fluid 
level at the time of installation and during continued oper-
ation of the compressor. The fluid level is to be checked 
when the compress
or is in the SHUT DOWN mode (fluid 
level may not be visible when operating), and by looking 
at the sight glass on the separator/sump tank. To be able 
to see the fluid level it may be necessary to start the 
machine and build the separator/sump tank pressure up 
to 10/20 psi and then shut down. Wait a few minutes to 
check oil level. If no fluid level is seen in the sight glass 
add fluid to the center of the glass. Do not overfill in any 
case. When a complete fluid change is performed, fill the 
separator/sump tank to the maximum allowable fluid 
level, which is center of the sight glass.
4.7 Electrical preparation
Interior electrical wiring is performed at the factory. 
Required customer wiring should be done by a qualified 
electrician in compliance with OSHA, National Electric 
Code and/or any applicable local electrical code concern-
ing isolation switches, fused disconn
ects, etc. Sullair pro-
vides a wiring diagram for use by the installer. An 
e
lectrical check should be made to help assure that the 
first start-up will be trouble-free. The compressor and 
drive should be properly grounded/earthed in accordance 
with Local and National Code requirements.
Installation of this compressor must 
be in accordance 
with recognized electrical codes and any local Health and 
Safety Codes.
Feeder cables should be sized by the customer/electrical 
co
ntractor to ensure that the circuit is balanced and not 
overloaded by other electrical equipment. The length of 
wiring from a suitable electrical feed point is critical as 
voltage drops may impair the performance of the com-
pressor. Cable sizes may vary consid
erably so the mains 
terminals will accept up to 50 mm2 (1 awg) (37/4 Sk & 
50
/60 H) and up to 90 mm2 (3/0 awg) (55/75 k & 75/
10
0 H) cable.
Feeder cable connections to incoming terminals L1-L2-
L3
 should be tight and clean.
The applied voltage must be comp
atible with the motor 
and compressor data plate ratings.
A starter hole is provided for incoming power connection. 
If it 
is necessary to make a hole in the control box in a dif-
ferent location, care should be t
aken to not allow metal 
shavings to enter the starter and other electrical compo-
nents within the box. If another hole is used, the original 
ho
le must be blocked off.
1. Check incoming voltage. Be sure that the 
inco
ming voltage is the same voltage that the 
compressor was wired for.
2. Check motor starter and overload heater 
sizes.
3. Check all electrical connections for tight-
ness.
4. Check the electrical controls by disconnect-
ing the three (3) motor leads from the starter. 
Energize the control circuits by pushing the 
 (Start) pad and check all protective 
devices to be sure that they will de-energize 
the starter coil when tripped.
5. Reconnect the three (3) motor leads and jog 
the motor for a direction of rotation check, as 
explained in Section 4.8: Motor rotation 
direction check on page 48.
4.8 Motor rotation direction check
Motor rotation check must be made at compressor start- 
up. The compressor can be damaged if it runs in the 
wrong direction for more than a few seconds. Motor rota-
tion can be viewed through the opening in the drive 
ad
apter housing. After the electrical wiring has been 
done, it is necessary to check the direction of the motor 
rotation. Pull out the EMERGENCY STOP button and 
press once, quickly and in succession, the   (Start) 
 NOTE
For low-volume systems that do not require an 
auxiliary separator/sump, compressor response 
time may need to be adjusted. Consult the Sul-
lair Service Department for assistance.
 DANGER
Lethal shock hazard inside. Disconnect all 
power at source before opening or servicing.