WS CONTROLLER
®SULLAIR®
3700 Operator’s Manual and Parts List
31
The list of displays may be navigated from either 
direction by using the Up “ ” or Down “ ” arrow 
keys.  For example, to change language from normal 
view, press the Up arrow pad once, press the Enter key 
“ ”, select your language, and press Enter again.  
The number of displays varies with compressor model, 
but will follow the pattern shown on the next page.
The large Emergency Stop button located near the 
controller overrides all electronic funtions to turn off 
control devices.  The controller senses this, and will 
display the fault as demonstrated above.  To reset, pull 
out the Emergency Stop button, then press the Stop pad 
to reset the WS controller.
5.4 LED LIGHTS
The four LED lights indicate the general condition of the 
machine.
The green Power indicator “ ” simply indicates that 
power is applied to the controller.  If will blink very slowly 
if the WS controller is set up to automatically restart after 
power failure.
The green Auto mode indicator “ ” indicates 
compressor operation is enabled.  It lights steadily if the 
motor is running.  If the motor stops while in Automatic 
mode, this LED will blink to indicate that the motor may 
restart.
The yellow Maintenance indicator “ ” comes on 
whenever there is recommended maintenance or a 
warning.  The text display will periodically indicate the 
recommended actions or the cause of the warning.  
The red Fault indicator “ ” indicates that a 
compressor fault has occurred and needs to be repaired 
before further operation.  The text display will indicate 
the cause of the fault.
The PC support program for the WS controller provides 
additional information about compressor operation and 
advanced setup adjustments to optimize operation.
Software part numbers are shown following a power 
interruption or other interruption of communication with 
the controller.  This remains on the display until 
satisfactory communications are established with the 
Input/Output module.