3700 Operator’s Manual and Parts List
 Figure 6-4
1. To Su mp Ta nk
2. Male Tube Connector
3. 90° Pipe Elbow
4. Filter Assembly*
5. Sight Glass/Orifice Block
6. Brass Plug Orifice
7. Female Tube Connector
8. To Unit
* Repair Kit P/N 02250117-782
F i g u r e   6 - 4        
Oil Return/Sight Glass
1. Disconnect the tube at bottom of sight glass.
2. Unscrew the sight glass assembly where the ell 
fitting joins the strainer/filter.
3. Remove used filter assembly, and replace with new 
assembly.
4. Inspect and clean the orifice inside the sight glass 
blocks. The orifice must be removed with an allen 
wrench.
5. Coat/lubricate the o-rings with silicone grease.
6. Reattach the connectors to the sight glass/orifice 
blocks.
PRESSURE REGULATOR ADJUSTMENT
Start the compressor and adjust the service valve to 
maintain service air pressure approximately at 5 psi over 
rated pressure. Turn the inlet valve regulator adjusting 
screw until air just begins to escape from the control air 
orifice (located at the bottom of the regulator; refer to 
Figure 6-5). Lock the adjusting screw in place with the 
locknut. The regulator is now properly set.
 Figure 6-5
1. Locking Nut
2. Adjustment Screw
F i g u r e   6 - 5        
Regulator Adjustment
WATER CONDENSATE DRAIN 
MAINTENANCE
If your compressor is fitted with the standard solenoid 
condensate drain valve, it is necessary to periodically 
clean the strainer. Remove the hex cap from the strainer 
and remove the strainer screen. Clean the screen and 
reinstall. If the screen is damaged, the strainer assembly 
must be replaced (P/N 241772).
CONTROL LINE STRAINER
The regulator and solenoid valve(s), which control the 
compressor, are protected by a strainer. Every 12 
months it is necessary to clean the strainer. Remove the 
hex cap from the strainer and remove the strainer 
screen. Clean the screen and reinstall. If the screen is 
damaged, the strainer assembly must be replaced (P/N 
241772).