31
375 Caterpillar Standard and Aftercooled/Filtered Operator’s Manual and Parts List
Section 5
MAINTENANCE
GENERAL5.1
Consistent and correctly performed maintenance will
ensure the compressor’s performance and extend its
operational life. See Part Replacement and Adjustment
Procedures on page 33 for a detailed description of
specic compressor components. Before performing
maintenance actions, read the CIMA Safety Manual, if
applicable. For engine maintenance requirements and
procedures, refer to the Engine Operator’s Manual.
DAILY MAINTENANCE5.2
See Initial Startup Shutdown/Procedure on page 30 for
general operation.
NOTE
Dispose of uids in accordance with
applicable federal, state and local
regulations.
WARNING
DO NOT remove caps. Plugs
and/or other components when
the compressor is running or
pressurized. Shutdown the
compressor before removing any
components.
NOTE
The radiator and engine cooling
system must be drained and ushed
every 1500 hours. Replace the
solution coolant with a 50% ethylene
glycol and 50% water solution or as
required for local climatic conditions.
DO NOT use a leak-sealing type
antifreeze. All engines must have
Supplemental Coolant Additive (SCA)
added to the engine coolant system.
Refer to the Engine Operator’s
Manual for specic requirements.
If uid must be added too frequently
at startup, a problem might have
developed causing an excessive
uid loss. See Trouble Shooting
on page 38 (Excessive Fluid
Consumption) for a probable cause
and remedy. After the compressor
has warmed-up, make a general
inspection of its components and
instrument panel to ensure that the
compressor is running properly.