SECTION 2 300HH, 375, 375H, 375HH, 425 AND 425H USER MANUAL R00
37
3. To acknowledge and hide the trouble code
and return to the single or four parameter
display, press the ENTER key.
IMPORTANT: Ignoring active trouble
codes can result in severe engine dam-
age.
4. The display will return to the single or four
parameter display, but the display will con-
tain the SHUTDOWN icon. Pressing the
ENTER key will redisplay the hidden trouble
code.
IMPORTANT: Ignoring active trouble
codes can result in severe engine dam-
age
.
5. Pressing the ENTER key once again will
hide the trouble code and return the screen
to the single or four parameter display.
6. The single or four parameter screen will dis-
play the shutdown icon until the trouble code
is corrected
IMPORTANT: Ignoring active trouble
codes can result in severe engine dam-
age.
PV101 SU_0000515
FAULT:
FUEL DELIVERY PRESSURE
CORRECTIVE ACTION
CHECK FUEL FILTER AND LINES
< NEXT >
Shutdown Message
SPN 100
SHUTDOWN
FMI 1
1 of x
Figure 2-36
PV101 SU_0000516
FAULT:
FUEL DELIVERY PRESSURE
CORRECTIVE ACTION
CHECK FUEL FILTER AND LINES
< NEXT >
Hide Trouble Code
SPN 100
SHUTDOWN
FMI 1
1 of x
Figure 2-37
1800 RPM
ENG RPM
PV101 SU_0000517
COOL TEMP
Flashing Shutdown Icon
1000 RPM
ENG RPM
57 PSI
57 F
COOL TEMP
12.4 VDC
BAT VOLT
OIL PRES
Figure 2-38
PV101 SU_0000518
FAULT:
FUEL DELIVERY PRESSURE
CORRECTIVE ACTION
CHECK FUEL FILTER AND LINES
< NEXT >
Redisplay Trouble Codes
SPN 100
SHUTDOWN
FMI 1
1 of x
Figure 2-39
PV101 SU_0000677
Shutdown Icon
1800 RPM
ENG RPM
COOL TEMP
1000 RPM
ENG RPM
57 PSI
57 F
COOL TEMP
12.4 VDC
BAT VOLT
OIL PRES
Figure 2-40