300HH, 375, 375H, 375HH, 425 AND 425H USER MANUAL R00 SECTION 5
72
Compressor does not achieve full 
discharge pressure
Run/start switch not in run position For compressors with idle warm-up 
controls, switch toggle to RUN for full 
operation
Air demand is excessive Check service lines for leaks or open 
valves
Dirty air filter Check the filter and change the 
element if required
Defective pressure regulator Check the diaphragm and replace 
with Kit if necessary
Defective idle warm-up control Replace control
Engine Warning/Shutdown lamp 
flashing—engine is derating
Turn the compressor OFF. Use 
PowerView menu and arrow keys to 
determine engine fault. Ignore the 
SSAM Flash Code. See the Engine 
Warning/Shutdown table for probable 
cause
Improper unloading with an excessive 
pressure build-up causing the 
pressure relief valve to open
Pressure regulating valve is set too 
high
Readjust
Control system leak causing loss of 
pressure signal
Check control lines
Defective pressure regulating valve. 
Repair valve (kit available)
Inlet valve jammed Free or replace valve
Restriction in the control system Check all control lines and 
components—ice and/or other 
contaminants could be the cause
Defective pressure relief valve 
opens when pressure is too low
Replace the pressure relief valve
Defective pressure regulator Check the diaphragm and replace 
with Kit if necessary
Insufficient air delivery Run/start switch not in run position For compressors with idle warm-up 
controls, switch toggle to RUN for full 
operation
Plugged air filter Replace
Defective idle warm-up control Replace control
Plugged air/fluid separator Replace separator element and also 
change compressor fluid and fluid 
filter
Defective pressure regulator Adjust or repair
Engine speed too low Readjust engine speed
Engine Warning/Shutdown lamp 
flashing—engine is derating
Turn the compressor OFF. Use 
PowerView menu and arrow keys to 
determine engine fault. Ignore the 
SSAM Flash Code. See the Engine 
Warning/Shutdown table for probable 
cause
Excessive compressor fluid 
consumption
Clogged return line Clear orifice and return line strainer
Lubrication system leak Check all pipes, connections and 
components
Separator element damaged or 
malfunctioning
Change separator element