SECTION 3 4500P-7500 USER MANUAL
35
16 SERIES UNIT/ AXIAL FAN MACHINE WEIGHTS
MAIN MOTOR HP WEIGHT
4500 60 ODP EE 2,755 LBS (1,249 kg)
4500 60 TEFC EE 3,121 LBS (1,415 kg)
5500 75 ODP EE 2,826 LBS (1.281 kg)
5500 75 TEFC EE 3,150 LBS (1,428 kg)
7500 100 ODP EE 3,178 LBS (1,441 kg)
7500 100 TEFC EE 3,427 LBS (1,554 kg)
4500 60 ODP PE 2,889 LBS (1,310 kg)
4500 75 ODP PE 3,075 LBS (1,394 kg)
5500 75 TEFC PE 3,189 LBS (1,446 kg)
7500 100 ODP PE 3,242 LBS (1,470 kg)
7500 100 TEFC PE 3,386 LBS (1,535 kg)
16 SERIES UNIT/CENTRIFUGAL FAN MACHINE WEIGHTS
MAIN MOTOR HP WEIGHT
4500 60 ODP EE 2,790 LBS (1,265 kg)
4500 60 TEFC EE 3,156 LBS (1,431 kg)
5500 75 ODP EE 2,861 LBS (1,297 kg)
5500 75 TEFC EE 3,185 LBS (1,444 kg)
7500 100 ODP EE 3,213 LBS (1,457 kg)
7500 100 TEFC EE 3,432 LBS (1,556 kg)
4500 60 ODP PE 2,924 LBS (1,326 kg)
4500 60 TEFC PE 3,202 LBS (1,452 kg)
5500 75 ODP PE 3,110 LBS (1,410 kg)
5500 75 TEFC PE 3,224 LBS (1,462 kg)
7500 100 ODP PE 3,277 LBS (1,463 kg)
7500 100 TEFC PE 3,421 LBS (1,551 kg)
18 SERIES UNIT/ AXIAL FAN MACHINE WEIGHTS
MAIN MOTOR HP WEIGHT
5500 75 ODP EE 2,798 LBS (1,269 kg)
5500 75 TEFC EE 3,164 LBS (1,435 kg)
7500 100 ODP EE 2,869 LBS (1,301 kg)
7500 100 TEFC EE 3,193 LBS (1,448 kg)
5500 75 ODP PE 3,221 LBS (1,461 kg)
5500 75 TEFC PE 3,440 LBS (1,560 kg)
7500 100 ODP PE 3,355 LBS (1,521 kg)
7500 100 TEFC PE 3,666 LBS (1,662 kg)
18 SERIES UNIT/ CENTRIFUGAL FAN MACHINE WEIGHTS
MAIN MOTOR HP WEIGHT
5500 75 ODP EE 2,833 LBS (1,285 kg)
5500 75 TEFC EE 3,199 LBS (1,451 kg)
7500 100 ODP EE 2,904 LBS (1,317 kg)
7500 100 TEFC EE 3,228 LBS (1,464 kg)
5500 75 ODP PE 3,256 LBS (1,476 kg)
5500 75 TEFC PE 3,475 LBS (1,576 kg)
7500 100 ODP PE 3,320 LBS (1,505 kg)
7500 100 TEFC PE 3,631 LBS (1,647 kg)
CFM COOLING AIR
CENTRIFUGAL FAN 60HZ HIGH STATIC: 8100
CENTRIFUGAL FAN 50HZ: 7300
AXIAL FAN: 8400
A1: ALTERNATE INCOMING POWER SUPPLY LOCATION Ø 2.50
[63.5]
A2: SPACE REQUIRED TO OPEN DOORS TYP. SEE NOTE #6
A3: SPACE REQUIRED TO OPEN STARTER PANEL
A4: CONTROLLER
A5: E-STOP
A6: OIL LEVEL SIGHTGLASS
A7: AIR INLET
A8: EXHAUST AIR OUT
A9: CONTAINMENT PAN DRAIN
A10: INCOMING CUSTOMER POWER SUPPLY Ø 3.0 (76.2)
A11: MOISTURE DRAIN CONNECTION 1/4"-18 NPT
NOTES:
1. Allow 4.00 feet [1.25 meters] minimum clearance around machine
for access and free circulation of air.
2. A foundation or mounting capable of supporting the weight of
package, and rigid enough to maintain the compressor frame level is
required.
3. All dimensions are ± .50" [12.7mm]
4. Recommended incoming customer power supply is shown on
drawing.
5. If ductwork is to be installed for cooling air high static fan must be
selected. max allowable additional static pressure 0.75 in h o with
high static fan.
6. Doors are removable using lift-off hinge pins.
7. All dimensions shown in inches with millimeter dimensions in
parentheses.
2