SECTION 2 600H, 700HH, 750, 750H, 750HH, 825, 900H, 1050 USER MANUAL
31
2.8 PIPING AND INSTRUMENTATION DIAGRAM—LP/HP DUAL (100-175 PSI)
Key Qty Description
1 1 FILTER, AIR
2 1 GAUGE, AIR FILTER RESTRICTION
3 1 INLET VALVE
4 1 COMPRESSOR
5 2 VALVE, RELIEF
6 1 SWITCH, TEMPERATURE
7 1 SENSOR, TEMPERATURE
8 3 SENSOR, PRESSURE
9 1 SEPARATOR, OIL
10 1 RECEIVER, AIR/OIL
11 1 GLASS, SIGHT OIL LEVEL
12 1 VALVE, MINIMUM PRESSURE
13 3 VALVE, BALL
14 1 COOLER, AIR
15 1 SEPARATOR, MOISTURE
16 1 TRAP, DRAIN
17 2 ORIFICE
18 1 VALVE, RUNNING BLOWDOWN N.C.
19 1 SIGHTGLASS, ORIFICE BLOCK
20 1 VALVE, THERMAL BYPASS
21 1 COOLER, OIL
22 1 FILTER, OIL
23 1 VALVE, RECIRCULATION N.C.
24 2 VALVE, CONTROL PRESSURE REGULATOR
25 1 GAUGE, PRESSURE
26 1 VALVE, SHUTTLE
27 2 VALVE, CHECK
28 1 VALVE, SOLENOID 3-WAY RUN/START
29 1 VALVE, SOLENOID 2-WAY ELECT
30 1 SEPARATOR, ELEMENT
31 1 VAVLE, REDUCING PRESSURE REGULATOR
32 2 VALVE, PRESSURE DIFF. BYPASS
33 4 STRAINER
34 3 VALVE, DRAIN
35 1 SEPARATOR, CONTROL MOISTURE
NOTES:
P1 DRY SIDE PRESSURE
P2 CONTROL PRESSURE
P3 WET SIDE PRESSURE
T1 COMPRESSOR DISCHARGE TEMPERATURE SENSOR
T3 RECEIVER TANK TEMPERATURE SWITCH (RTT)
Key Qty Description