MANDATORY TO MAINTAIN WARRANTY
DE-18 SHUT DOWN / PREVENTIVE
MAINTENANCE PROCEDURE
MANDATORY – IF MACHINE IS NO LONGER IN SERVICE AND IS TO BE REMOVED FROM
JOBSITE OR RETURNED TO YARD. THE FOLLOWING SERVICE IS TO BE PERFORMED
WITHIN 24 – 48 HOURS OF SHUT DOWN. THIS PROCESS MUST BE DOCUMENTED.
• The air end must be rotated 8-10 times. Do not allow the engine to start.
Rotate machine by hand or by using the engine’s starter motors. The object is to
rotate the air end so as to not allow condensate debris to create a restriction thus
binding the second stage air end.