SECTION 5 DE-18 USER MANUAL
61
C267 INPUTS AND OUTPUTS
P1 = Interstage Discharge Pressure
P2 = Discharge Pressure
P3 = Oil Filter Out Pressure
P4 = Oil Filter In Pressure
T1 = 1st Stage Discharge Temperature
T2 = 2nd StageDischarge Temperature
T3 = Oil Filter Out Temperature
T4 = 2nd Stage Inlet Temperature
T5 = Discharge Temperature
247 PIN 247 Pin Capability Input Use Signal Type Description
J1-1 Output #7
Digital Transistor Spare
J1-2 Output #5
Digital Transistor Compressor fault light
J1-3 Output #3
Digital Transistor Compressor alarm light
J1-4 Output #1
Digital Transistor Not used
J1-5 Power 2
Power Power
J1-6 Output #8
Digital Transistor Spare
J1-7 Output #6
Digital Transistor Spare
J1-8 Output #4
Digital Transistor Spare
J1-9 Output #2
Digital Transistor Drain #1#2
J1-10 Power 2
Power Power
J2-1 Analog 6
Analog 4-20mA Oil filter out temperature T3
J2-2 Analog 4
Analog 4-20mA 2nd stage discharge temp. T1
J2-3 Analog 2
Analog 4-20mA 1st stage discharge temp. T1
J2-4 Input 8
Digital Switch Spare
J2-5 Input 6
Digital Switch Spare
J2-6 Input 4
Digital Switch Spare
J2-7 Input 2
Digital Switch CADP1 compressor air differential
pressure switch #1
J2-8 Frequency Input
Frequency Not used
J2-9 Power ground
J2-10 Analog 7
Analog 0-5 VDC Spare
J2-11 Analog 5
Analog 4-20mA T6 comp. oil temperature
J2-12 Analog 3
Analog 4-20mA T5 discharge temperature
J2-13 Analog 1
Analog 4-20mA T4 stage inlet temperature
J2-14 Input 7
Digital Switch Spare
J2-15 Input 5
Digital Switch Not used
J2-16 Input 3
Digital Switch CAT ECM diagnostic
J2-17 Input 1
Digital Switch CAT ECM warning
J2-18 Power 1