Section 5
ShopTek™ ST4, ST5, ST7, ST11, ST15 Three-phase 60 Hz User Manual 5: Operation
88292018-236 R00
Subject to EAR, ECCN EAR99 and related export control restrictions. 39
Operation
5.1 Routine operation
Before starting the compressor, check the fluid level in
the separator tube. If sight glass is not completely full,
add the required amount of fluid to bring it to its proper
level. Frequent addition of fluid indicates the presence of
a leak or a condition causing excessive fluid consump-
tion. See the Section 6.12: Troubleshooting on
page 51
under “Excessive compressor fluid consumption” for a
p
robable cause and corrective action.
After a routine start, observe the controller display for the
pr
oper indications for this phase of operation. After the
compressor has warmed up, check all compressor oper-
ation indications to ensure that it is running properly.
WARNING
High pressure hazard
Removing caps, plugs, and/or other components
wh
en compressor is running or pressurized
could result in death or serious injury.
Do not
remove caps, plugs, and/or other com-
ponents when compressor is running or pressur-
ized. Stop compressor and reliev
e all internal
pressure before removing caps, plugs, and/or
other components.