2. Changing the Pressure Settings
    The control pressure can be changed with the
    switches shown below on the control panel.
    An energy saving operation can be performed to
    lower wasted energy by lowering the maximum (stop)
    pressure. The normal pressure settings of the air
    compressor are shown in the figure to the right.
    Under the Muti-Drive control mode, the delivery
    pressure is to be above the “recovery pressure +
    12/15psig”, and will not reach the maximum setting
    pressure normally. Under Multi-Drive control mode,
    more energy savings is possible by lowering the
    recovery pressure.
■ Procedure for changing the control pressure setting
   Press the "Stop" switch, and drop the pressure in the air receiver to 70psig (4.8 bar) and below (it is
   impossible to change the control pressure setting if the pressure in the air receiver is 71psig (4.9 bar
   and above). Once the pressure in the air receiver is 70psig (4.8 bar) and below the control pressure
   setting can be changed by following the procedure below.
15
Operation (continued)
Pressure Setting
122PSIG Model 145PSIG Model
Maximum (Stop)
Pressure [psig (bar)]
122 (8.4) 145 (10.0)
Recovery (Start)
Pressure [psig (bar)]
110 (7.6) 115 (7.9)
 
Digital Display
  Steps
 5 & 6
  Steps
 2, 3 & 4
  Steps
 2 & 4
Steps Digital display
1
Verify that the pressure is indicated on the digital display.  
2
Press  the  stop  switch  and  then  press  the  start  switch  and  hold  both  buttons  for  5 
seconds to change the digital display to PC.
3
To  change  the  maximum  (stop)  pressure,  press  the  start  switch.  The  digital  display 
changes to H122 (indicating what the digital display will be for the pressure settings from 
the factory).
4
Pressing the stop switch will lower the maximum pressure setting by 1 PSIG. 
Pressing the start switch will raise the maximum pressure setting by 1 PSIG.
5
After the change in pressure setting has been set, press the Screen Shift switch 
and the digital display will change to PC.
6
Pressing  the  Screen  Shift  switch  again  will change the digital display to the pressure 
display.
To change the recovery (start) pressure, press the stop switch in step 3 above to change the 
digital display  to L110  (this is an  example of  what the  digital display will be for  the pressure 
settings from the  factory)  and then change  the  pressure settings as  shown  in steps 4  and 
later.  
EX. 122PSIG Model