USER MANUAL
Oil Free Scroll Compressor
SRL-7.5MB, SRL-11MB, SRL-16.5MB
Users are required to read
the entire User Manual before
handling or using the product.
Keep the User Manual in a safe
place for future reference.
SAFETY WARNING
Failure to follow the instructions
and procedures in this manual,
or misuse of this equipment, will
void
its warranty.
WARRANTY NOTICE
10 – 22 hp (7.5 – 16.5 kW)
PART NUMBER:
02250236-267 R02
The information in this manual is current as of its
publication date and applies to compressor models
indicated on this cover until next revision of this manual
or release of a replacement manual.
Publication date: 02/01/2019
Copyright © 2019 Sullair, LLC. All rights reserved.
Subject to EAR, ECCN EAR99 and related export control restrictions.

Questions and Answers

  • M
    mcmahonveronicaAug 16, 2025
    What should I do if my Sullair Air Compressor displays a pressure sensor error?
    • A
      Amanda LopezAug 16, 2025
      Tighten the pressure sensor wire and reset the air compressor. If the error re-occurs, contact the local Sullair distributor to replace the pressure sensor.
  • B
    Bradley AdamsAug 22, 2025
    How to reduce excessive noise from my Sullair SRL-16.5MB?
    • C
      Chelsea NguyenAug 22, 2025
      Excessive noise may be due to several factors. Ensure the air compressor is installed on level ground according to the installation procedure. Check if transport fixtures were not removed and remove them. Also, re-tighten or replace the V-belt if it is loose. If the rubber vibration isolators are worn, they should be replaced. For issues related to the SRL reverse rotation, scroll head failure, or electric motor failure, contact your local Sullair distributor.
  • M
    Mary GloverAug 25, 2025
    What to do if my Sullair SRL-16.5MB Air Compressor has low discharge pressure?
    • K
      Kevin VasquezAug 25, 2025
      Low discharge pressure can be caused by a few things. First, check for leaks in the internal air compressor piping and re-tighten all the air compressor pipe fittings. If the safety relief valve is leaking, replace it. A clogged or dirty intake air filter can also cause this issue, so replace the intake air filter element. For check valve failure, contact the local Sullair distributor.
  • M
    Megan HarrisAug 27, 2025
    What causes high discharge pressure in my Sullair SRL-16.5MB?
    • T
      Teresa HarrisonAug 27, 2025
      High discharge pressure can be caused by a printed circuit board failure or electromagnetic contactor failure. Contact the local Sullair distributor to replace these components.
  • J
    Jason HensleyAug 30, 2025
    Why is the electric motor overheating in my Sullair SRL-16.5MB Air Compressor?
    • J
      Julia SalazarAug 30, 2025
      Overheating of the electric motor may be due to a failed motor bearing, a worn seal, or a short-circuited motor. Contact the local Sullair distributor to replace the electric motor.
  • C
    Charles LynchSep 1, 2025
    How do I fix a phase reversal error on my Sullair Air Compressor?
    • K
      Kimberly WrightSep 1, 2025
      To fix a phase reversal error, change two of the three incoming power cables.
  • S
    Shannon WallaceSep 4, 2025
    How to troubleshoot an ambient temperature sensor error on a Sullair SRL-16.5MB Air Compressor?
    • C
      Christopher LinSep 4, 2025
      Check the temperature sensors and the wiring to verify that they are not broken and the connectors are not disconnected. Reset the air compressor, and if the error re-occurs, contact the local Sullair distributor.
  • L
    lanemarySep 7, 2025
    What does the maintenance alarm mean on my Sullair SRL-16.5MB Air Compressor?
    • L
      Lindsay JonesSep 7, 2025
      This alarm is displayed when the total operating hours exceed 2,500 hours. Carry out inspection and maintenance of the air compressor.
  • M
    Michele CastroSep 10, 2025
    What does the scroll head maintenance alarm indicate on my Sullair Air Compressor?
    • L
      Lauren LeeSep 10, 2025
      This alarm shows when the total operating hours exceed 9,500 hours (145PSIG Model : 4,500 hours). Perform an inspection and maintenance of the scroll head.
  • J
    Jennifer SmithSep 13, 2025
    What triggers the overhaul alarm on my Sullair SRL-16.5MB Air Compressor?
    • M
      Michael GuerraSep 13, 2025
      This alarm appears when the total operating hours exceed between 19,000 to 19,500 hours (145PSIG Model : between 13,500 to 14,500 hours). Carry out overhaul of the Scroll Head.

Summary

Safety Precautions

Installation Safety Precautions

Guidelines for safely installing the air compressor in various environments.

Operation Safety Precautions

Essential safety measures for operating the air compressor equipment.

Maintenance and Inspection Safety Precautions

Safety protocols for performing maintenance and inspection on the compressor.

Installation

Product Confirmation

Procedures to verify the correct model and included items upon delivery.

Transporting the Air Compressor

Guidelines and precautions for moving the air compressor safely.

Installing the Air Compressor

Instructions for proper placement, ventilation, and spacing for installation.

Operation

Maintenance and Inspection

Troubleshooting

Digital Display Error and Alarm Indications

Explanation of error codes and alarms displayed on the digital panel.

Digital Display Error and Alarm Indications (Optional function)

Troubleshooting for optional function error codes and alarms.