USER MANUAL
Oil Free Scroll Compressor
SRL-7.5MB, SRL-11MB, SRL-16.5MB
Users are required to read
the entire User Manual before
handling or using the product.
Keep the User Manual in a safe
place for future reference.
SAFETY WARNING
Failure to follow the instructions
and procedures in this manual,
or misuse of this equipment, will
void
its warranty.
WARRANTY NOTICE
10 – 22 hp (7.5 – 16.5 kW)
PART NUMBER:
02250236-267 R02
The information in this manual is current as of its
publication date and applies to compressor models
indicated on this cover until next revision of this manual
or release of a replacement manual.
Publication date: 02/01/2019
Copyright © 2019 Sullair, LLC. All rights reserved.
Subject to EAR, ECCN EAR99 and related export control restrictions.

Questions and Answers

  • W
    whitney27Aug 16, 2025
    What should I do if my Sullair Air Compressor displays a pressure sensor error?
    • A
      Annette FernandezAug 17, 2025
      Tighten the pressure sensor wire and reset the air compressor. If the error re-occurs, contact the local Sullair distributor to replace the pressure sensor.
  • J
    Joanna StevensAug 22, 2025
    How to reduce excessive noise from my Sullair SRL-7.5MB Air Compressor?
    • R
      rogercollinsAug 22, 2025
      Excessive noise may be due to several factors. Ensure the air compressor is installed on level ground according to the installation procedure. Check if transport fixtures were not removed and remove them. Also, re-tighten or replace the V-belt if it is loose. If the rubber vibration isolators are worn, they should be replaced. For issues related to the SRL reverse rotation, scroll head failure, or electric motor failure, contact your local Sullair distributor.
  • M
    Michelle DrakeAug 25, 2025
    What to do if my Sullair Air Compressor has low discharge pressure?
    • M
      Michael HarrisAug 26, 2025
      Low discharge pressure can be caused by a few things. First, check for leaks in the internal air compressor piping and re-tighten all the air compressor pipe fittings. If the safety relief valve is leaking, replace it. A clogged or dirty intake air filter can also cause this issue, so replace the intake air filter element. For check valve failure, contact the local Sullair distributor.
  • B
    Brian YoungAug 27, 2025
    What causes high discharge pressure in my Sullair Air Compressor?
    • D
      Dr. Joseph WeissAug 27, 2025
      High discharge pressure can be caused by a printed circuit board failure or electromagnetic contactor failure. Contact the local Sullair distributor to replace these components.
  • T
    Tyler MurphyAug 30, 2025
    Why is the electric motor overheating in my Sullair Air Compressor?
    • J
      John GoldenAug 30, 2025
      Overheating of the electric motor may be due to a failed motor bearing, a worn seal, or a short-circuited motor. Contact the local Sullair distributor to replace the electric motor.
  • D
    davidnealSep 2, 2025
    How do I fix a phase reversal error on my Sullair SRL-7.5MB Air Compressor?
    • B
      Barry BeardSep 2, 2025
      To fix a phase reversal error, change two of the three incoming power cables.
  • R
    Rachel BoydSep 5, 2025
    How to troubleshoot an ambient temperature sensor error on a Sullair SRL-7.5MB?
    • L
      Laura DonovanSep 5, 2025
      Check the temperature sensors and the wiring to verify that they are not broken and the connectors are not disconnected. Reset the air compressor, and if the error re-occurs, contact the local Sullair distributor.
  • W
    walkerkatherineSep 7, 2025
    What does the maintenance alarm mean on my Sullair Air Compressor?
    • S
      Stephanie JohnsonSep 7, 2025
      This alarm is displayed when the total operating hours exceed 2,500 hours. Carry out inspection and maintenance of the air compressor.
  • T
    Tyler RyanSep 10, 2025
    What does the scroll head maintenance alarm indicate on my Sullair SRL-7.5MB?
    • L
      lunajuanSep 12, 2025
      This alarm shows when the total operating hours exceed 9,500 hours (145PSIG Model : 4,500 hours). Perform an inspection and maintenance of the scroll head.
  • K
    Kevin HoustonSep 12, 2025
    What triggers the overhaul alarm on my Sullair SRL-7.5MB?
    • B
      Briana PittmanSep 13, 2025
      This alarm appears when the total operating hours exceed between 19,000 to 19,500 hours (145PSIG Model : between 13,500 to 14,500 hours). Carry out overhaul of the Scroll Head.

Summary

Safety Precautions

Operation Safety Precautions

Safety measures related to operating the air compressor.

Maintenance and Inspection Safety Precautions

Safety measures for performing maintenance and inspection.

Installation

Product Confirmation

Verifying the correct model and included items.

Transporting the Air Compressor

Procedures for moving the air compressor safely.

Installing the Air Compressor

Guidelines for placing and setting up the air compressor.

Piping the Air Compressor

Connecting the air compressor to the air receiver system.

Wiring the Air Compressor

Connecting the main power supply and internal wiring.

Remote Input and Output Signals

Details on terminal block connections for remote control.

Operation

Control Panel Descriptions

Explanation of the control panel indicators and switches.

Prior to Operation

Steps and settings before starting the air compressor.

Changing the Pressure Settings

Procedure to adjust maximum and recovery pressure settings.

Start Up

Step-by-step guide for starting the air compressor.

Daily Operation

Procedures for starting and stopping the compressor daily.

Maintenance and Inspection

Daily Maintenance and Inspection Procedures

Daily tasks for maintaining the air compressor.

Inspection for Loose Bolts, Nuts and Screws

Checking and tightening fasteners for safety and function.

Intake Air Filter Inspection

Procedure for inspecting and replacing the intake air filter.

Inspection of the Ventilating Fan

Verifying the proper operation of the cooling fans.

500 Hours and;or 2 Months Maintenance and Inspection Procedures

Maintenance tasks required at 500-hour or 2-month intervals.

Check Valve Inspection

Inspecting the check valve for leaks or reverse rotation.

V-belt Inspection

Checking V-belts for noise, slippage, or damage.

Intake Air Filter Replacement

Replacing the intake air filter periodically.

10,000 Hours and;or 4 Years Maintenance and Inspection Procedures

Key maintenance tasks at 10,000-hour or 4-year intervals.

Rubber Hose Replacement

Replacing the rubber hose at specified intervals.

Check valve

Checking the check valve for wear and potential malfunction.

20,000 Hours and;or 8 Years Maintenance and Inspection Procedures

Key maintenance tasks at 20,000-hour or 8-year intervals.

Troubleshooting

Digital Display Error and Alarm Indications

Understanding error codes and alarm messages displayed on the unit.

Digital Display Error and Alarm Indications (Optional function)

Details on optional error and alarm indications.

ID Drawings

ID Drawing: SRL-7.5 MB

Diagram showing dimensions and component locations for SRL-7.5MB.

ID Drawing: SRL-11 MB

Diagram showing dimensions and component locations for SRL-11MB.

ID Drawing: SRL-16.5 MB

Diagram showing dimensions and component locations for SRL-16.5MB.

Wiring Diagram

Standard Specifications

Log Book

Sullair SRL-7.5MB Specifications

General IconGeneral
BrandSullair
ModelSRL-7.5MB
CategoryAir Compressor
LanguageEnglish