Subject to EAR, ECCN EAR99 and related export control restrictions.  02250236-267 R02
1. Ensure that a properly sized air receiver is installed [80 gallons (303 liters) or more]. Without a properly
  sized air receiver, it is possible that the air compressor can be damaged due to excessive starts and stops.
2. Use a textile reinforced, heat resistant rubber hose (hydraulic) of appropriate rating (see page S-2) to
    connect the Oil Free Scroll Air Compressor to the air receiver.
■ It is necessary to install a properly sized air receiver to this compressor in order to reduce excessive
    starts and stops.
■ Without a properly sized air receiver, it is possible that the main motor or electromagnetic contactor may
    receive unwarranted wear due to excessive starts and stops.
7
● Use a heat resistant, pressure tight rubber hose (see page S-2) to connect the Oil Free Scroll Air
   Compressor to the air receiver. The rubber hose will prevent damage to the air receiver due to vibration.
● Use of an improper rubber hose may lead to cracks and/or leaks due to hose deterioration.
● Do not operate the air compressor when the stop valve between the air receiver and the air
    compressor is closed.
● Do not install heavy objects, such as drain traps and filters, to the compressed air discharge as they
    may damage the discharge line of the air compressor.
● If a remote vertical air receiver is installed, attach the air receiver to the ground with foundation bolts.
WARNING
 4  Piping the Air Compressor
Safety Relief Valve
● If a stop valve is installed
    in the middle of the
    compressed air piping,
    install a safety relief valve
    between the air
    compressor and the stop 
    valve.
Vertical Air Receiver
● To avoid damage to the air
    compressor due to excessive
    starts and stops, a properly sized
    air receiver must be installed.
Hose Fitting
Rubber Hose
● A textile reinforced, heat
    resistant rubber hose
   (hydraulic)(see page S-2)
    is recommended to
    connect the equipment.
Stop Valve
● Make sure to install a
    stop valve between the air
    compressor and the air 
    receiver.
Installation(continued)
● Without a properly sized air receiver, it is possible that a serious accident may occur due to the
    unwarranted wear of the main motor or electromagnetic contactor.
● For the protection of the air compressor, if excessive starts and stops occur the compressor will
    shut off and display cycle error [E.CY]. This will stop the supply of compressed air.
● The error message cycle error [E.CY] is an indication that the volume of air receiver is insufficient
    for proper operation. An increase in the volume of the air receiver will eliminate the cycle error [E.CY].
WARNING