EasyManua.ls Logo

Sullair SRL-7.5MB - Piping the Air Compressor

Sullair SRL-7.5MB
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Subject to EAR, ECCN EAR99 and related export control restrictions. 02250236-267 R02
1. Ensure that a properly sized air receiver is installed [80 gallons (303 liters) or more]. Without a properly
sized air receiver, it is possible that the air compressor can be damaged due to excessive starts and stops.
2. Use a textile reinforced, heat resistant rubber hose (hydraulic) of appropriate rating (see page S-2) to
connect the Oil Free Scroll Air Compressor to the air receiver.
■ It is necessary to install a properly sized air receiver to this compressor in order to reduce excessive
starts and stops.
■ Without a properly sized air receiver, it is possible that the main motor or electromagnetic contactor may
receive unwarranted wear due to excessive starts and stops.
7
Use a heat resistant, pressure tight rubber hose (see page S-2) to connect the Oil Free Scroll Air
Compressor to the air receiver. The rubber hose will prevent damage to the air receiver due to vibration.
Use of an improper rubber hose may lead to cracks and/or leaks due to hose deterioration.
● Do not operate the air compressor when the stop valve between the air receiver and the air
compressor is closed.
Do not install heavy objects, such as drain traps and filters, to the compressed air discharge as they
may damage the discharge line of the air compressor.
If a remote vertical air receiver is installed, attach the air receiver to the ground with foundation bolts.
WARNING
4 Piping the Air Compressor
Safety Relief Valve
If a stop valve is installed
in the middle of the
compressed air piping,
install a safety relief valve
between the air
compressor and the stop
valve.
Vertical Air Receiver
To avoid damage to the air
compressor due to excessive
starts and stops, a properly sized
air receiver must be installed.
Hose Fitting
Rubber Hose
A textile reinforced, heat
resistant rubber hose
(hydraulic)(see page S-2)
is recommended to
connect the equipment.
Stop Valve
Make sure to install a
stop valve between the air
compressor and the air
receiver.
Installation(continued)
Without a properly sized air receiver, it is possible that a serious accident may occur due to the
unwarranted wear of the main motor or electromagnetic contactor.
● For the protection of the air compressor, if excessive starts and stops occur the compressor will
shut off and display cycle error [E.CY]. This will stop the supply of compressed air.
● The error message cycle error [E.CY] is an indication that the volume of air receiver is insufficient
for proper operation. An increase in the volume of the air receiver will eliminate the cycle error [E.CY].
WARNING

Related product manuals