24
Maintenance and Inspection
(continued)
Maintenance and Overhaul hours interval time chart
Running Hours
Air Compressor
Package
Scroll Head
Maintenance and
Overhaul : 122PSIG
2,500Hrs.
Alarm Reset
Alarm Output (Maintenance)
Alarm Output (Overhaul)
5,000Hrs. 7,500Hrs. 10,000Hrs. 15,000Hrs. 20,000Hrs. 25,000Hrs. 30,000Hrs. 35,000Hrs. 40,000Hrs. 45,000Hrs.
2,500Hrs.
2,500Hrs.
Alarm Reset
Alarm Output (Maintenance)
Alarm Reset
Alarm Output (Maintenance)
9,500Hrs.
9,500 Hrs.
"A"Hrs.
Overhaul Alarm Output : 19,000 + "A" Hrs. ("A" < 500Hrs.)
Alarm Reset
9,500 Hrs. × 9,500 Hrs.
Alarm Reset
Alarm Output (Maintenance)
"B"Hrs.
Overhaul Alarm Output : 19,500Hrs. ("B" > 500Hrs.)
Scroll Head
Maintenance and
Overhaul : 145PSIG
Alarm Output (Maintenance)
Alarm Reset
Alarm Output (Maintenance)
4,500Hrs.
4,500 Hrs.
"A"Hrs.
Maintenance Alarm Output : 9,500 Hrs. ("A" > 500Hrs.)
Alarm Reset
4,500 Hrs.
Alarm Reset
Alarm Output (Overhaul)
Maintenance Alarm Output : 9,000 + "A" Hrs. ("A" < 500Hrs.)
"C"Hrs.
Overhaul Alarm Output : 4,500 + "C" Hrs. (between 13,500 and 14,500 Hrs.)
"B"Hrs.