4. Install the red nylon washer and the locknut on the supply coupling. Torque the locknut to
54 Nm (40-ft. lbs.). See Figure 15.
Figure 15 Install Supply Coupling Washer and Locknut
5. Connect the adsorber’s self-sealing coupling on its inlet side to the oil separator’s outlet
coupling. With two wrenches, torque the Aeroquip coupling to 47 ± 7 Nm (35 ± 5 ft. lbs.).
See Figure 16.
Figure 16 Connect Self-Sealing Coupling