EasyManua.ls Logo

Sumitomo HF-520 Series - Page 105

Sumitomo HF-520 Series
272 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
104
4.6 Basic Drive Setup Adjustments
Step Display/Result
1. Turn on the power to the drive. The initial display appears.
2. Set the frequency reference to F6.00 (6 Hz).
3. Press the key to start the motor.
4. The motor should accelerate up to 6 Hz while the RUN light is on.
STOP
off on
5.
Press the
STOP
key to stop the motor. The RUN light will ash
until the motor comes to a complete stop.
flashing
off
Run the Drive using Digital Input Terminals: b1-02 = 1
This setting uses the digital input terminals to enter the run command. The factory setting
is a 2-Wire sequence.
Using a 2-Wire Sequence
Digital Input Terminals ON OFF
S1 Forward Run Stop
S2 Reverse Run Stop
S1
S2
SC
Drive
Forward Run
Reverse Run
Digital Input Common
Figure 4.13 Example Wiring Diagram for 2-Wire Sequence