93
Start-Up Programming
& Operation
4
4.5 Application Selection
No. Parameter Name Default Setting
E1-03 V/f Pattern Selection 0FH
L2-01 Momentary Power Loss Operation Selection 1: Enabled
L3-04
Stall Prevention Selection during
Deceleration
1: Enabled
Table 4.12 Compressor: User Parameters (A2-01 to A2-16):
No. Parameter Name No. Parameter Name
b1-01 Frequency Reference Selection 1 E1-03 V/f Pattern Selection
b1-02 Run Command Selection 1 E1-07 Middle Output Frequency
b1-04 Reverse Operation Selection E1-08 Middle Output Frequency Voltage
C1-01 Acceleration Time 1 E2-01 Motor Rated Current
C1-02 Deceleration Time 1
Setting 6: Hoist Application
Note: 1. Read the instructions listed on page 97 when using Hoist Application Preset.
2. Perform Auto-Tuning after selecting the Hoist Application Preset.
3. If UL3 appears on the operator display after Auto-Tuning is complete, set L6-01 to 0 to repeat the Auto-Tuning
process.
Table 4.13 Hoist: Parameters and Settings
No. Parameter Name Default Setting
A1-02 Control Method Selection 2: Sensorless Vector Control
b1-01 Frequency Reference Selection 1 0: Operator
b6-01 Dwell Reference at Start 3.0 Hz
b6-02 Dwell Time at Start 0.3 s
C1-01 Acceleration Time 1 3.0 s
C1-02 Deceleration Time 1 3.0 s
C6-01 Drive Duty Selection 0: Heavy Duty
C6-02 Carrier Frequency Selection 2: 5 kHz
d1-01 Frequency Reference 1 6.0 Hz
d1-02 Frequency Reference 2 30.0 Hz
d1-03 Frequency Reference 3 60.0 Hz
E1-03 V/f Pattern Selection 0FH
H2-02 Terminals P1 Function Selection 37: During Frequency Output