B.2 Parameter Table
No. Name Description
Analog Output
Level
Unit
Control
Mode
Addr.
Hex
V/f SV
U2-13
Drive Operation Status at
Previous Fault
Displays the operation status of the drive
at the previous fault. Displays the same
status displayed in U1-12.
No signal output
avail.
A A 8C
U2-14
Cumulative Operation
Time at Previous Fault
Displays the cumulative operation time at
the previous fault.
No signal output
avail.
1 H A A 8D
U2-15
Soft Starter Speed
Reference at Previous
Fault
Displays the run speed after a soft start
when a previous fault occurred. Displayed
as in U1-16.
No signal output
avail.
0.01
%
A A 7E0
U2-16
Motor q-Axis Current at
Previous Fault
Displays the q-axis current for the motor at
the previous fault.
No signal output
avail.
0.10
%
A A 7E1
U2-17
Motor d-Axis Current at
Previous Fault
Displays the d-axis current for the motor at
the previous fault.
No signal output
avail.
0.10
%
A 7E2
U3: Fault History
Use U3 monitors to display fault data. <3>
U3-01 Most Recent Fault Displays the most recent fault.
No signal output
avail.
A A
90
(800)
U3-02 2nd Most Recent Fault Displays the second most recent fault.
No signal output
avail.
A A
91
(801)
U3-03 3rd Most Recent Fault Displays the third most recent fault.
No signal output
avail.
A A
92
(802)
U3-04 4th Most Recent Fault Displays the fourth most recent fault.
No signal output
avail.
A A
93
(803)
U3-05 5th Most Recent Fault Displays the fth most recent fault.
No signal output
avail.
A A 804
U3-06 6th Most Recent Fault Displays the sixth most recent fault.
No signal output
avail.
A A 805
U3-07 7th Most Recent Fault Displays the seventh most recent fault.
No signal output
avail.
A A 806
U3-08 8th Most Recent Fault Displays the eighth most recent fault.
No signal output
avail.
A A 807
U3-09 9th Most Recent Fault Displays the ninth most recent fault.
No signal output
avail.
A A 808
U3-10 10th Most Recent Fault Displays the tenth most recent fault.
No signal output
avail.
A A 809
U3-11
Cumulative Operation
Time at Most Recent
Fault
Displays the cumulative operation time at
the most recent fault.
No signal output
avail.
1 h A A
94
(80A)
U3-12
Cumulative Operation
Time at 2nd Most Recent
Fault
Displays the cumulative operation time at
the second most recent fault.
No signal output
avail.
1 h A A
95
(80B)
U3-13
Cumulative Operation
Time at 3rd Most Recent
Fault
Displays the cumulative operation time at
the third most recent fault.
No signal output
avail.
1 h A A
96
(80C)
U3-14
Cumulative Operation
Time at 4th Most Recent
Fault
Displays the cumulative operation time at
the fourth most recent fault.
No signal output
avail.
1 h A A
97
(80D)
U3-15
Cumulative Operation
Time at 5th Most Recent
Fault
Displays the cumulative operation time at
the fth most recent fault.
No signal output
avail.
1 h A A 80E