Sun Fire 280R Server Product Notes 7
Instructions for Installing a Server Into a
Sun Rack 900
The 280R server rackmounting kit now includes M6 screws for use with the Sun
Rack 900 or any cabinet with mounting holes sized for metric dimensions. Table 1
describes the additional screws.
To install a server into Sun Rack 900, follow the instructions in the Sun Fire 280R
Server Setup and Rackmounting Guide. Where the instructions specify 10-32 screws,
use the M6 screws included in the rackmounting kit box. Use a Phillips No. 3
screwdriver with the M6 screws.
Before you install the server into the cabinet, replace the 10-32 captive screws on
the front trim panel with M6 x 20 cheese head screws.
Hardware Issues
Clarification of System Depth Dimension
(BugID 4756551)
The Site Planning Guide for Entry-Level Servers (part number 816-1613) lists the depth
of the Sun Fire 280R system as 69.21 cm (27.25 in). This is the correct depth
excluding the front bezel measurement. The depth of the system including the front
bezel measurement is 73.8 cm (29.12 in).
TABLE 1 M6 Screws in Rackmounting Kit
Screws Qty Use
M6 x 20 panhead screws
with washers
P/N: 240-4374-01
8 Attach the slide assemblies to the front
and back mounting rails.
M6 x 20 cheese head screws
P/N: 240-4459-01
4 Use in trim panels instead of the 10-32
screws to secure the top and bottom of
the server to the front mounting rails.