Quarter -Turn Electric Valve Actuator【OM Series】 Sun Yeh Ele. Ind. Co., Ltd. | 2021.11
f. Supply power to the fully-open position. Screw in the Open (left) Mechanical end
stop screw until it bottoms out (refer to P.11 4.4.2), then turn back for 1/2-1 turn
based on the actuator model listed below.
OM-2 to OM-6, OM-F, OM-G and OM-H:1 turn
OM-7 to OM-8:3/4 turn
OM-9 to OM-13:1/2 turn
g. Tighten the locknut. (Max. Torque:5.88 Nm )
h. Supply power to the fully-open position. Screw in the Open (right) Mechanical end
stop screw until it bottoms out (refer to P.11 4.4.2), then turn back for 1/2-1 turn
based on the actuator model listed below.
OM-2 to OM-6, OM-F, OM-G and OM-H:1 turn
OM-7 to OM-8:3/4 turn
OM-9 to OM-13:1/2 turn
i. Tighten the locknut. (Max. Torque:5.88 Nm )
j. Supply the power to confirm that the limit switches achieve the fully open-close
stroke.
k. When choosing modulating units or VR:
Supply power to run the actuator to the fully-closed position. Adjust the gear and
the set screws based on the actuator model listed below.
l. The setting procedure is now completed.
Rotate the round gear counter-clockwise to the
end and tighten the M5 set screw.
Rotate the round gear clockwise to the end and
tighten the M5 set screw.
OM-2 to OM-13
OM-F, OM-G and OM-H
Rotate the sector gear clockwise to the end and
tighten the M5 set screw.
M5 Set Screw
【OM-1, OM-A, OM-AM and OM-J】
【OM-2 to OM-13, OM-F, OM-G and OM-H】