12/24/36/48V automatic recognition
before boost or equalization charging stage
14~14.8/28~29.6/42~44.4/56~59.2V@25℃(default:14.5/29/43.5/58V)
14~15/28~30/42~45/56~60V@25℃ (default:14.8/29.6/44.4/59.2V)
(Liquid, AGM)
13~14.5/26~29/39~43.5/52~58V@25℃(default:13.7/27.4/41.1/54.8V)
10.8~11.8/21.6~23.6/32.4~35.4/43.2~47.2V
(Default:11.2/22.4/33.6/44.8V)
11.4~12.8/22.8~25.6/34.2~38.4/45.6~51.2V(default:12/24/36/48V)
Max volt on Bat. terminal
-4.17mV/K per cell (Boost, Equalization) ,-3.33mV/K per cell (Float)
10.0~64.0V (Lithium, default: 29.4V)
9.2~63.8V (Lithium, default: 28.7V)
9.0~60.0V (Lithium, default: 21.0V)
9.6~62.0V (Lithium, default: 22.4V)
Gel, AGM, Liquid, Lithium default: Gel
150V (-20℃), 138V(25℃)
*1
3.0~10.0/6.0~20.0/9.0~30.0/12.0~40.0V (Default: 8/16/24/32V)
(Battery Voltage + 1.0V)~Voc*0.9
*2
Always on, Street lamp, User-defined Mode (default: Always on)
≤16mA (12V); ≤12mA (24/36/48V)
IoT, BLE(Internal/External)
*1. Maximum solar panel voltage at minimum ambient operating temperature.
*2. Voc: PV-Module open circuit voltage.
*3. Slash separate values for 12V, 24V, 36V and 48V nominal system voltage.