EasyManua.ls Logo

SUNESS EV-5.12M - Precaution and Installation; 4.1 Precaution; 4.2 Installation; Emergency Response

Default Icon
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LiFePO4 Battery System LiFePO4 Battery System
EV-5.12M
5.12KWH
200Ah
25.6V
80A
100A
45KG
24V-28.8V
IEC62619,UN38.3,CE
Charging Temp Range
Discharging Temp Range
0~55°C
-10~55°C
5.1 Warning labels
6.1 Battery module specifications
2
3. SAFETY
4. PRECAUTION AND INSTALLATION
5. EMERGENCY RESPONSE
Fire situation
4.2 Installation
Any operation on the batteries should be handled by authorized technicians, it is understood that the technicians
should familiarize themselves with this manual before any maintenance or installation is carried out on the system.
4.1 Precaution
• Do not expose battery to open flame.
• Do not place the product under direct sunlight.
• Do not place the product near flammable materials, it may lead to fire or explosion.
• Store in a cool and dry place with space.
• Store the product on a flat surface.
• Store the product out of reach of children and animals.
• Do not damage the unit by dropping, deforming, impacting, cutting or penetrating with a sharp object. It may
cause leakage of electrolyte or fire.
• Do not touch any liquid spilled from the product. There is a risk of electric shock or damage to skin.
Always handle the battery wearing the insulated gloves.
• Do not step on the product or place any foreign objects on it. This can result in damage.
• Do not charge or discharge damaged battery.
After unpacking, please check the product if there is any damage or miss part.
• Make sure that the inverter and battery is completely turned off before commencing installation.
• Do not interchange the positive and negative terminals of the battery.
• Ensure that there is no short circuit of the terminals or with any external device.
• Do not exceed the battery voltage rating of the inverter.
• Do not connect the battery to any incompatible inverter.
• Do not connect batteries with different types.
• Please ensure that all the batteries are grounded.
• Do not open the battery to repair or disassemble. Only SUNESS technicials are allowed to carry out any such
repairs.
• ln case of fire, use only dry powder fire extinguisher. Liquid extinguishers should not be used.
• Install the battery away from children or pets.
• Do not use battery in high static environment where the protection device might be damaged.
• Do not install with other brand batteries or cells.
The batteries comprise of multiple batteries connected in series, It is designed to prevent hazards or failures.
However, SUNESS cannot guarantee absolute safety. Under exposure to the internal materials of the battery
the following recommendations should be carried out by the user.
EV-5.12M photovoltaic energy storage system is a 24V energy storage system based on Lithium Iron phosphate
battery. lt is equipped with a customized battery management system(BMS), Which is designed for energy storage
applications of household photovoltaic power generation users. ln the daytime, the excess power of photovoltaic
generation can be stored in the battery. During the night or as required, the stored energy can be provided to the
electrical equipment and appliances, it can improve the use efficiency of photovoltaic power generation, peak
shaving, and provide emergency standby power.
6. PRODUCT INFORMATION
8,000 Cycle@ 80% DOD / 25 / 0.5C, 60%EOL°C
10 years
660×430×185MM