118
Parameters SH5T SH6T
Rated grid frequency 50 / 60Hz
Grid frequency range
45 - 55Hz / 55 - 65Hz
Harmonic (THD) <3% (of rated power)
Power factor at Rated power
/ Adjustable power factor
> 0.99 / 0.8 leading to 0.8 lagging
Feed-in phases/connection
phases
3 / 3 - N - PE
Backup data(on grid mode)
Max. output power for backup
load
43000W
Max. output current for back-
up load
3*63A
Backup data(off-grid mode)
Rated voltage 3 / N / PE, 220 / 380 V; 230 / 400 V; 240 / 415 V (± 2 %)
Rated frequency 50Hz / 60Hz (± 0.2 %)
THDV(@Linear load)
< 2%
Backup switch time
<10ms
Rated output power
5000 W / 5000 VA 6000 W / 6000 VA
Peak output power **
10000 W / 10000 VA,10s 12000 W / 12000 VA,10s
Rated output current for
backup load during on grid
mode
43000 W / 43000 VA (25℃)
Efficiency
Max. efficiency / European
efficiency
97.9 % / 97.2 % 97.9% / 97.3 %
Protection & Function
Grid monitoring
Yes
DC reverse polarity
protection
Yes
AC short-circuit protection
Yes
Leakage current protection
Yes
DC switch (solar) Yes
Surge Protection DC Type II / AC Type II ***
PID Zero Yes
Parallel operation on grid port Master-slave mode
Battery input reverse polarity
protection
Yes
General Data
11 Appendix User Manual