63
6.8.2.1 Smart Energy Meter Connection
The Smart Energy Meter is mainly used to detect the direction and magnitude of the current.
The Smart Energy Meter DTSU666–20 is used (provided in the box), please connect Pin A
on the meter to Pin A2 on the inverter and Pin B on the meter to Pin B2 on the inverter.
Contact SUNGROW to ensure that the Smart Energy Meter model is available
locally.
The meter data may not be used for billing purposes.
The inverter is equipped with the feed-in power limit function, so as to meet the re-
quirements of some national standards or grid standards for the output power at
the grid connection point.The export control functionality has not been tested to
AS/NZS 4777.2:2020.
Smart Energy Meter Wiring Diagram
The Smart Energy Meter wiring diagram is presented as follows:
User Manual 6 Electrical Connection