55--11
Consumable parts shall not be guaranteed even in warranty period.
5-1) CHECK POINTS FOR REGULAR INSPECTION
1) Clean, oil, and grease the set parts of the machine on a regular basis.
2) Inspect tension of each driver belt.
3) Failure to perform regular inspections may cause the following:
·Corrosion of P/C circuit board
·Damage to the semi-conductor on P/C circuit board
·Malfunction of the floppy disk drive
·Ill connection of the connector
·Abnormal wear-out of machine parts due to insufficient oiling and greasing
CAUTION
5-2) CLEANING
Safety rules must be observed during the inspection.
Turn OFF the main power before inspecting or cleaning of the following parts.
5
MAINTENANCE AND INSPECTION
CAUTION
SWF is not responsible for machine damages or malfunctions caused by insufficient cleaning
or oiling.
CAUTION
1
2
3
Reference Fig.
NO
Important Parts for Cleaning
Cleaning cycle
Every day
Once a week
(NOTE)
Remove the needle plate and pull the movable
blade forward (see picture).
Use the SWF brush to remove dirt and dust.
How to Clean
Around the hook
Guide rail to the take-up lever
Around the movable blade and the fixed blade
Once in 3-7 days