EasyManua.ls Logo

SunTech TANGO M2 Service Manual

SunTech TANGO M2
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
80-0056-00-SM-RevD 2017-12-13 SunTech Tango M2 Service Manual | 1
Tango M2
®
Tango M2 NIBP Stress Test Blood Pressure Monitor
Service Manual
SunTech Medical, Inc.
507 Airport Boulevard; Suite 117
Morrisville, North Carolina 27560-8200
United States of America
Toll free: 800.421.8626
Phone: +1.919.654.2300
Fax: +1.919.654.2301
SunTech Medical, Ltd.
Oakfield Industrial Estate
Stanton Harcourt Road
Eynsham, Oxfordshire OX29 4TS
United Kingdom
Phone: +44(0)1865.884.234
Fax: +44(0)1865.884.235

Other manuals for SunTech TANGO M2

Question and Answer IconNeed help?

Do you have a question about the SunTech TANGO M2 and is the answer not in the manual?

SunTech TANGO M2 Specifications

General IconGeneral
Measurement MethodOscillometric
Power Source4 AA batteries or AC adapter
ConnectivityUSB
DisplayLCD
TypeUpper Arm
UseProfessional
Measurement SiteUpper Arm
Accuracy (Pressure)±3 mmHg
MemoryUp to 99 readings
Device TypeBlood Pressure Monitor
Cuff Size22-32 cm (Adult)
Measurement Range (Pressure)0 to 300 mmHg
Measurement Range (Pulse)40-180 beats per minute
Accuracy (Pulse)±5%

Summary

Introduction to the Tango M2 Service Manual

Scope of the Tango M2 Service Manual

Regulatory Information and Symbols

Icons and Symbols Guide

Explains various icons and symbols used on the monitor and in its literature.

Tango M2 Inputs and Outputs

Tango M2 Input Ports and Components

Details the various input connections and components of the Tango M2 monitor.

Tango M2 Output Features

Describes the output features of the Tango M2 monitor, such as the display and beeper.

Tango M2 Combined Input/Output Connections

Covers combined input/output connections like pneumatic cables and serial/USB ports.

Operational Modes and Menu System

Normal Operation of the Tango M2

Explains the standard menu-driven operation using the keypad or host system.

Accessing the Diagnostics Menu

Introduces the hidden diagnostics menu for maintenance and advanced settings.

Routine Preventative Maintenance Procedures

Verification of Pressure Calibration

Describes the procedure to verify the pressure calibration accuracy of the monitor.

Setting the Calibration Parameters

Details the steps required to properly set the calibration for the Tango M2.

Performing a Leak Rate Test

Outlines the procedure for testing the pneumatic system's leak rate.

Safety Timeout Check Procedure

Explains how to perform the safety timeout check for the blood pressure monitor.

Overpressure Check Procedure

Details the steps for conducting the overpressure safety check on the device.

Non-Routine Maintenance and Disassembly

General Internal Inspection Guidelines

Provides instructions for internal inspection, including warranty considerations.

Disassembly Steps for the Tango M2

Step-by-step guide for disassembling the Tango M2 monitor, noting variants.

Reassembly Procedures for the Tango M2

Detailed instructions for reassembling the Tango M2 monitor after service.

Appendix 1: Spare Parts List

Appendix 2: Key to Exploded Views

Appendix 3: Tango M2 Monitor Assembly Diagram

Related product manuals