Installation and Operation Instructions
Superior™ DRT2000 and DRC2000
Direct-Vent Gas Fireplaces
P/N 900004-00 Rev. C 04/2014
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900004-02.
PFS
®
USC
Models
DRT2033xxx *
DRC2033xxx *
DRT2035xxx *
DRC2035xxx *
DRT2040xxx *
DRC2040xxx *
DRT2045xxx *
DRC2045xxx *
P900004-00
* “xxx” indicates unique model identifiers. This manual covers all Superior™
DRT2000 and DRC2000 models.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.
Une barrière conçue pour réduire le risque de brûlure
par le hublot chaude est fournie avec l’appareil et doit
être installé.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING AVERTISSEMENT AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE
AVANT D’Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE
TOUCHER LA SURFACE VITRÉE.
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA TOCAR
EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions dones dans cette notice pour duire au
minimum le risque d’incindie ou d’explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
s Do not try to light any appliance.
s Do not touch any electrical switch; do not
use any phone in your building.
s Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
s If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
s Ne pas tenter d’allumer d’appareil.
s Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
s Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
s Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.

Other manuals for Superior DRC2033

Questions and Answers

  • C
    christinesmithAug 15, 2025
    What to do if my Superior DRC2033 spark igniter will not light pilot?
    • J
      John AndersonAug 15, 2025
      If the spark igniter on your Superior Indoor Fireplace won't light the pilot, there are several potential causes. First, check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, the igniter may be defective and needs replacement. If there is a spark, try lighting the pilot with a match. If it lights, the gas mixture may be off, requiring a longer purge period. If it still doesn't light, check the gap at the electrode and pilot; it should be about 1/8 inch for a strong spark. If the gap is correct, the pilot might need replacing. Also, ensure the gas supply pressure is within the limits specified on the rating plate and that the pilot orifice is clean and not plugged.
  • J
    Joseph AndersonAug 18, 2025
    Why is my Superior DRC2033 Indoor Fireplace pilot burning but no gas to burner?
    • K
      Kimberly Woods DDSAug 18, 2025
      If the pilot light is on in your Superior Indoor Fireplace, but no gas is reaching the burner, and the valve knob and burner switch are both in the 'ON' position, several issues could be the cause. A defective wall switch or faulty wiring could be the problem; check the connections or try using a jumper wire across the terminals at the wall switch. Also, the thermopile may not be generating enough millivolts; it should read a minimum of 325 millivolts with the optional wall switch OFF. If it reads lower, the thermopile may need replacing. Additionally, a plugged burner orifice could be blocking the gas flow; inspect and clear any blockages. Finally, make sure that only one of the switches is in the ON position.
  • M
    Matthew OwensAug 21, 2025
    What to do if Superior DRC2033 Indoor Fireplace pilot will not stay lit?
    • J
      Jonathan FletcherAug 22, 2025
      If the pilot light on your Superior Indoor Fireplace won't stay lit after following the lighting instructions, the pilot flame might not be properly impinging on the thermocouple. Ensure the pilot flame makes good contact with the thermocouple. You may need to clean and/or adjust the pilot for maximum flame impingement. Also, check that the connection between the valve and thermocouple is tight and secure.
  • R
    Raymond FosterAug 26, 2025
    What causes frequent pilot/burner outage problem in Superior DRC2033 Indoor Fireplace?
    • T
      Thomas MyersAug 26, 2025
      Frequent pilot/burner outages in your Superior Indoor Fireplace can be caused by a pilot flame that is too low or too high. Clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple. This will help prevent the pilot/valve safety from dropping out.
  • D
    debbiejohnsonAug 28, 2025
    What to do if Superior DRC2033 Indoor Fireplace main burner does not light but the igniter is sparking?
    • D
      Donna NelsonAug 28, 2025
      If the main burner on your Superior Indoor Fireplace doesn't light even though the igniter is sparking, first check the gas supply and shutoff valves to ensure gas is reaching the fireplace. Inspect the control compartment for any loose wiring to the valve or ignition module, if necessary, call a service technician. If there is air in the gas line, purge the gas line of air, if required, call a service technician. Also, check and replace the unit battery backup.
  • T
    Thomas VasquezSep 1, 2025
    What to do if nothing happens when Superior DRC2033 is turned ON/OFF?
    • M
      Mr. Jordan YoungSep 1, 2025
      If nothing happens when you turn your Superior Indoor Fireplace ON or OFF, first ensure that the wall switch plate is set to REMOTE. Next, check the gas supply and gas shutoff valves to confirm that gas is reaching the fireplace. Finally, check or replace the backup batteries behind the wall plate.
  • E
    Ethan ColonSep 4, 2025
    What causes soot on the logs and glass of my Superior Indoor Fireplace?
    • T
      Thomas PittmanSep 4, 2025
      Soot on the logs and glass of your Superior Indoor Fireplace can result from several factors. Ensure the logs are properly positioned. A white film may develop on the glass during initial operation of the fireplace. Clean the glass after each use until the film disappears. Check and adjust the vent restrictor setting and air shutter opening according to the instructions in this manual.
  • S
    sandersdawnSep 7, 2025
    Why does my Superior DRC2033 Indoor Fireplace main burner come on but then goes out?
    • A
      April ThomasSep 7, 2025
      If the main burner of your Superior Indoor Fireplace comes on but then goes out, check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Inspect the control compartment for any loose wiring to the valve or ignition module, if necessary, call a service technician. Also, if the pilot flame is not engulfing the sensor or the vent system is obstructed, call a service technician.
  • J
    Jesus TerrellSep 12, 2025
    Why does my Superior Indoor Fireplace have poor flame and/or blue flame?
    • D
      Diana YoungSep 12, 2025
      A poor or blue flame in your Superior Indoor Fireplace can be caused by a door seal that is not properly aligned, leading to gaps and air leaks. Remove and realign the door to ensure the gasket seal is fully engaged around the door frame.

Summary

General Information

Important Safety Information

Crucial safety guidelines for fireplace operation and installation. Covers hazards and precautions.

Fireplace Installation, Operation, and Maintenance Notices

Notices regarding installation, operation, and maintenance. Warns against alterations and improper procedures.

Installation

Packaging

Details the components included with the fireplace heater upon delivery.

Introduction

Overview of the direct-vent gas fireplaces, their design, and power requirements.

Approved Vent Components

Specifies the required and approved vent system components for safe operation.

Codes and Standards

Lists compliance with safety standards and codes for installation.

Vent Termination Clearances

Vertical Vent Termination Clearances

Specifies minimum clearances for vertical vent terminations based on roof pitch.

Horizontal Vent Termination Clearances

Details minimum clearances for horizontal vent terminations to walls and other structures.

Minimum Clearances to Combustibles

Fireplace And Vent Clearances

Defines minimum clearances required between the fireplace/vent and combustible materials.

Installation Preparation

Installation Sequence

Framing

Steps related to constructing the fireplace framing and ensuring proper support.

Venting

Steps involved in selecting and installing the vent system components.

Electrical Connection

Procedure for connecting electrical power to the fireplace unit.

Gas Connection

Steps for connecting the gas supply line to the fireplace.

Finishing

Final installation steps including optional components and aesthetic finishes.

Vent System Preparation

Select a Horizontal or Vertical Vent System

Guidance on choosing between horizontal and vertical vent system configurations.

Install the Vent System

Install the Vertical Termination Vent System

Detailed instructions for installing the vertical vent termination.

Install the Horizontal Termination Vent System

Venting with Secure Flex Kits

Complete the Field Wiring

Millivolt Wiring

Wiring instructions for millivolt gas valve systems.

Electronic Wiring

Wiring instructions for electronic gas valve systems.

Connect the Gas Line

Verify Proper Fireplace Operation

Millivolt Fireplace Inspection

Steps for inspecting millivolt fireplace operation, including pilot flame.

Electronic Fireplace Inspection

Steps for inspecting electronic fireplace operation.

Adjust Air Shutter for Flame Appearance

Attach Safety-in-Operation Warning Labels

Attaching Safety-in-Operation Warnings

Instructions for properly affixing safety labels to controls and transmitters.

Accessory Components

Paint and Blower Kits

Details touch-up paint and forced air blower kit options.

Firebox Decorative Elements

Components for enhancing the firebox interior, like glass media and embers.

Fireplace Liners and Guards

Includes brickaded firebox liner kits and vent termination guards.

Control Systems

Various thermostatic and ON/OFF/timer control kits for fireplace operation.

Lighting Instructions

Millivolt Gas Valve Lighting

Step-by-step guide for lighting the pilot and burner on millivolt systems.

Turning Off Gas Supply

Procedure for safely shutting off the gas supply to the appliance.

Electronic Gas Valve Lighting

Troubleshooting

Replacement Parts

Warranty

Superior DRC2033 Specifications

General IconGeneral
ModelDRC2033
Fuel TypeElectric
Voltage120V
VentingVent-Free
Remote ControlYes
TimerYes
Heating Capacity400 sq ft
ThermostatYes
Safety FeaturesOverheat Protection

Related product manuals