Installation and Operation Instructions
Superior™ DRT2000 and DRC2000
Direct-Vent Gas Fireplaces
P/N 900004-00 Rev. G 04/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900004-02.
PFS
®
USC
Models
DRT2033xxx *
DRC2033xxx *
DRT2035xxx *
DRC2035xxx *
DRT2040xxx *
DRC2040xxx *
DRT2045xxx *
DRC2045xxx *
P900004-00
* “xxx” indicates unique model identifiers. This manual covers all Superior™
DRT2000 and DRC2000 models.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
L’écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
Report No. F13-094

Other manuals for Superior DRC2035

Questions and Answers

  • J
    Joseph WhiteSep 3, 2025
    Why does my Superior Indoor Fireplace have poor flame and/or blue flame?
    • Q
      qfoleySep 3, 2025
      A poor or blue flame in your Superior Indoor Fireplace can be caused by a door seal that is not properly aligned, leading to gaps and air leaks. Remove and realign the door to ensure the gasket seal is fully engaged around the door frame.
  • R
    Rodney CampbellSep 18, 2025
    Why does my Superior Indoor Fireplace have a poor or blue flame?
    • T
      Tyler EvansSep 18, 2025
      If you're experiencing a poor flame or a blue flame in your Superior Indoor Fireplace, it could be due to the door seal not being properly aligned, causing gaps and air leaks. Remove and realign the door so the gasket seal is fully engaged around the door frame.
  • V
    vreyesSep 16, 2025
    Why is there soot on the logs and glass of my Superior Indoor Fireplace?
    • J
      Justin MartinSep 16, 2025
      If you notice soot on the logs and glass of your Superior Indoor Fireplace, it could be due to several reasons. First, excessive flame impingement on the logs may be the cause; ensure the logs are properly positioned as detailed on Page 54. A white film may develop on the glass during the first few fires as part of the burn-in process, in that case, clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED). Also, check the vent restrictor setting and adjust the air shutter adjustment lever according to the instructions in this manual. Finally, make sure the air shutter is properly opened by pushing in the rod.
  • R
    Ryan Taylor Jr.Sep 15, 2025
    Why does the main burner on my Superior Indoor Fireplace turn on and then go out?
    • E
      emitchellSep 15, 2025
      If the main burner on your Superior Indoor Fireplace comes on but then goes out, first check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Also, check the control compartment for any loose wiring to the valve or ignition module (it is recommended to call a service technician). Other potential causes, which require a service technician, include the pilot flame not engulfing the sensor or an obstructed vent system.
  • W
    watkinsjoySep 13, 2025
    Why does my Superior Indoor Fireplace pilot/burner frequently go out?
    • B
      Brittany GlassSep 13, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Indoor Fireplace, the pilot flame may be too low or too high, causing the pilot/valve safety to drop out. Try cleaning and/or adjusting the pilot flame to ensure maximum flame impingement on the thermocouple.
  • D
    David BraySep 12, 2025
    What to do if nothing happens when I turn my Superior Indoor Fireplace on or off?
    • A
      Allen RaySep 12, 2025
      If nothing happens when you turn your Superior Indoor Fireplace ON or OFF, first check that the wall switch plate is set to REMOTE. Then, check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Finally, check or replace the backup batteries behind the wall plate to ensure the unit is receiving power.
  • D
    Deborah SmithSep 10, 2025
    Why won't the pilot light stay lit on my Superior Indoor Fireplace?
    • D
      Daniel MckenzieSep 10, 2025
      If the pilot light won't stay lit on your Superior Indoor Fireplace, even after following the lighting instructions, the issue might be a defective pilot generator (thermocouple). Check that the pilot flame is properly hitting the thermocouple. Clean and/or adjust the pilot to ensure maximum flame impingement on the thermocouple. Also, make sure the connection between the valve and thermocouple is tight and secure.
  • D
    Dustin LeonSep 8, 2025
    What to do if the main burner doesn't light on my Superior Indoor Fireplace but the igniter is sparking?
    • A
      Ashley LeeSep 8, 2025
      If the igniter is sparking but the main burner on your Superior Indoor Fireplace isn't lighting, start by checking the gas supply and shutoff valves to ensure gas is reaching the fireplace. Then, inspect the control compartment for any loose wiring to the valve or ignition module; if you find any loose wires, call a service technician. Also, there might be air in the gas line, which would require purging (it is recommended to call a service technician). Finally, make sure the unit is receiving power by replacing the unit's battery backup.
  • S
    stranSep 5, 2025
    What to do if the spark igniter won't light the pilot on my Superior Indoor Fireplace?
    • M
      Miranda GarciaSep 5, 2025
      If the spark igniter on your Superior Indoor Fireplace isn't lighting the pilot, there could be several reasons. First, check for a spark at the electrode and pilot. If there's no spark, and the electrode wire is properly connected, the igniter may be defective and needs replacement. If there is a spark, try lighting the pilot with a match. If it lights, the gas mixture might be off, requiring a longer purge period. If it still doesn't light, check the gap at the electrode and pilot; it should be about 1/8 inch for a strong spark. If the gap is correct, the pilot might need replacing. Also, make sure the gas supply pressure is within the limits specified on the rating plate. Finally, the pilot orifice could be plugged, so try cleaning or replacing it.
  • R
    Richard AdamsAug 21, 2025
    What to do if my Superior DRC2035 Indoor Fireplace spark igniter will not light pilot?
    • W
      William MorrisonAug 21, 2025
      If the spark igniter on your Superior Indoor Fireplace won't light the pilot, there are several potential causes. First, check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, the igniter may be defective and needs replacement. If there is a spark, try lighting the pilot with a match. If it lights, the gas mixture may be off, requiring a longer purge period. If it still doesn't light, check the gap at the electrode and pilot; it should be about 1/8 inch for a strong spark. If the gap is correct, the pilot might need replacing. Also, ensure the gas supply pressure is within the limits specified on the rating plate and that the pilot orifice is clean and not plugged.

Summary

Safety and Warnings

General Safety Precautions

Crucial safety precautions for operation, installation, and potential hazards.

Burn Hazard Warnings

Alerts about hot glass and surfaces, keeping children away.

Fire and Explosion Hazards

Warnings regarding flammable materials and gas leaks.

Fireplace Installation Procedures

Installation Sequence and Framing

Step-by-step guide and framing requirements for installation.

Venting and Clearances

Instructions for vent system installation and termination clearances.

Connections and Finishing

Gas/electrical connections, and final component installation.

Operation and Maintenance

Lighting Instructions

Step-by-step guide for lighting the fireplace.

Installing Decorative Components

Procedures for installing decorative logs, stone, and glass media.

Air Shutter and Flame Adjustment

How to adjust the air shutter for proper flame appearance.

Maintenance Schedule

Recommended maintenance tasks and frequencies.

Troubleshooting Common Issues