EasyManua.ls Logo

Superior DRC2040 - User Manual

Superior DRC2040
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation and Operation Instructions
Superior™ DRT2000 and DRC2000
Direct-Vent Gas Fireplaces
P/N 900004-00 Rev. G 04/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900004-02.
PFS
®
USC
Models
DRT2033xxx *
DRC2033xxx *
DRT2035xxx *
DRC2035xxx *
DRT2040xxx *
DRC2040xxx *
DRT2045xxx *
DRC2045xxx *
P900004-00
* “xxx” indicates unique model identifiers. This manual covers all Superior™
DRT2000 and DRC2000 models.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
L’écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
Report No. F13-094

Other manuals for Superior DRC2040

Questions and Answers

  • S
    Shannon WilliamsSep 3, 2025
    Why does my Superior DRC2040 have poor flame and/or blue flame?
    • M
      Matthew HendrixSep 3, 2025
      A poor or blue flame in your Superior Indoor Fireplace can be caused by a door seal that is not properly aligned, leading to gaps and air leaks. Remove and realign the door to ensure the gasket seal is fully engaged around the door frame.
  • M
    Michael MercadoSep 18, 2025
    Why does my Superior Indoor Fireplace have a poor or blue flame?
    • S
      shannon76Sep 18, 2025
      If you're experiencing a poor flame or a blue flame in your Superior Indoor Fireplace, it could be due to the door seal not being properly aligned, causing gaps and air leaks. Remove and realign the door so the gasket seal is fully engaged around the door frame.
  • R
    richardsonkristenSep 17, 2025
    Why is there soot on the logs and glass of my Superior Indoor Fireplace?
    • J
      John Stanley Jr.Sep 17, 2025
      If you notice soot on the logs and glass of your Superior Indoor Fireplace, it could be due to several reasons. First, excessive flame impingement on the logs may be the cause; ensure the logs are properly positioned as detailed on Page 54. A white film may develop on the glass during the first few fires as part of the burn-in process, in that case, clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED). Also, check the vent restrictor setting and adjust the air shutter adjustment lever according to the instructions in this manual. Finally, make sure the air shutter is properly opened by pushing in the rod.
  • R
    Ricky KingSep 15, 2025
    Why does the main burner on my Superior Indoor Fireplace turn on and then go out?
    • J
      johnsonmichaelSep 15, 2025
      If the main burner on your Superior Indoor Fireplace comes on but then goes out, first check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Also, check the control compartment for any loose wiring to the valve or ignition module (it is recommended to call a service technician). Other potential causes, which require a service technician, include the pilot flame not engulfing the sensor or an obstructed vent system.
  • J
    johnsonlisaSep 13, 2025
    Why does my Superior Indoor Fireplace pilot/burner frequently go out?
    • M
      Mary TerrySep 13, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Indoor Fireplace, the pilot flame may be too low or too high, causing the pilot/valve safety to drop out. Try cleaning and/or adjusting the pilot flame to ensure maximum flame impingement on the thermocouple.
  • G
    Gary JohnsonSep 12, 2025
    What to do if nothing happens when I turn my Superior Indoor Fireplace on or off?
    • M
      michael85Sep 12, 2025
      If nothing happens when you turn your Superior Indoor Fireplace ON or OFF, first check that the wall switch plate is set to REMOTE. Then, check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Finally, check or replace the backup batteries behind the wall plate to ensure the unit is receiving power.
  • J
    James MathewsSep 10, 2025
    Why won't the pilot light stay lit on my Superior Indoor Fireplace?
    • M
      Michael MoranSep 12, 2025
      If the pilot light won't stay lit on your Superior Indoor Fireplace, even after following the lighting instructions, the issue might be a defective pilot generator (thermocouple). Check that the pilot flame is properly hitting the thermocouple. Clean and/or adjust the pilot to ensure maximum flame impingement on the thermocouple. Also, make sure the connection between the valve and thermocouple is tight and secure.
  • C
    Christopher JuarezSep 8, 2025
    What to do if the main burner doesn't light on my Superior Indoor Fireplace but the igniter is sparking?
    • J
      Jamie HartmanSep 8, 2025
      If the igniter is sparking but the main burner on your Superior Indoor Fireplace isn't lighting, start by checking the gas supply and shutoff valves to ensure gas is reaching the fireplace. Then, inspect the control compartment for any loose wiring to the valve or ignition module; if you find any loose wires, call a service technician. Also, there might be air in the gas line, which would require purging (it is recommended to call a service technician). Finally, make sure the unit is receiving power by replacing the unit's battery backup.
  • A
    Annette HawkinsSep 5, 2025
    What to do if the spark igniter won't light the pilot on my Superior Indoor Fireplace?
    • M
      mbryanSep 5, 2025
      If the spark igniter on your Superior Indoor Fireplace isn't lighting the pilot, there could be several reasons. First, check for a spark at the electrode and pilot. If there's no spark, and the electrode wire is properly connected, the igniter may be defective and needs replacement. If there is a spark, try lighting the pilot with a match. If it lights, the gas mixture might be off, requiring a longer purge period. If it still doesn't light, check the gap at the electrode and pilot; it should be about 1/8 inch for a strong spark. If the gap is correct, the pilot might need replacing. Also, make sure the gas supply pressure is within the limits specified on the rating plate. Finally, the pilot orifice could be plugged, so try cleaning or replacing it.
  • S
    Stacey LarsenAug 21, 2025
    What to do if my Superior Indoor Fireplace spark igniter will not light pilot?
    • W
      William BookerAug 21, 2025
      If the spark igniter on your Superior Indoor Fireplace won't light the pilot, there are several potential causes. First, check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, the igniter may be defective and needs replacement. If there is a spark, try lighting the pilot with a match. If it lights, the gas mixture may be off, requiring a longer purge period. If it still doesn't light, check the gap at the electrode and pilot; it should be about 1/8 inch for a strong spark. If the gap is correct, the pilot might need replacing. Also, ensure the gas supply pressure is within the limits specified on the rating plate and that the pilot orifice is clean and not plugged.

Summary

General Information

IMPORTANT SAFETY INFORMATION

Critical safety warnings and precautions for operating the fireplace.

Installation

Approved Vent Components

Lists approved venting systems and components for installation.

Codes and Standards

Compliance with national and local safety codes and standards.

Orifice Sizes-Sea Level to High Altitude

Burner orifice sizes for different elevations and gas types.

REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS

Specific installation requirements for Massachusetts.

MANUFACTURED HOME REQUIREMENTS

Guidelines for installing the appliance in manufactured homes.

LOCATION

Considerations for selecting the optimal installation location.

VENT TERMINATION CLEARANCES

Minimum clearances required for vent terminations.

MINIMUM CLEARANCES TO COMBUSTIBLES

Required clearances from combustible materials.

INSTALLATION SEQUENCE

Step-by-step guide for the entire installation process.

Framing

Instructions for constructing the fireplace framing.

Venting

Steps for selecting and installing the vent system.

Electrical Connection

Procedures for connecting electrical power to the fireplace.

Gas Connection

Steps for connecting the gas supply line.

Finishing

Final steps including glass door, logs, and adjustments.

Route the Gas Supply Line to the Fireplace

Guidance on routing the gas supply line.

Install the [Optional] Blower Kit before Installation in the Framing

Instructions for installing the optional blower kit.

Place the Fireplace in the Framing and Secure

Steps for positioning and securing the fireplace in the frame.

Select a Horizontal or Vertical Vent System

Guidance on selecting the appropriate vent system.

Install the Vent Restrictor (if necessary)

Procedures for installing the vent restrictor.

Connecting the vent pipe

How to connect vent pipe sections and components.

Install the Vertical Termination Vent System

Instructions for terminating vertical vent systems.

Install the Horizontal Termination Vent System

Instructions for terminating horizontal vent systems.

Complete the Field Wiring

Steps for completing the electrical field wiring.

Connect the Gas Line

Instructions for connecting the gas supply line.

Verify Proper Fireplace Operation

Procedures to check and ensure proper fireplace operation.

Adjust the Air Shutter to Ensure Proper Flame Appearance

How to adjust the air shutter for optimal flame appearance.

Attach the Safety-in-Operation Warning Labels

Proper placement of safety warning labels.

Operation

CARBON MONOXIDE POISONING

Information on symptoms and actions for carbon monoxide poisoning.

Accessing the Control Compartment

Instructions for accessing the fireplace control compartment.

Continuous Pilot Ignition Switch

Explanation of the continuous pilot ignition switch modes.

Traditional Only: Installing the Firebox Liners

Steps for installing firebox liners in traditional models.

Contemporary Only: Installing the Glass Media

Steps for installing glass media in contemporary models.

Installing the logs, volcanic stone, and glowing embers

Proper placement of logs, stone, and embers for safe combustion.

Installing the DRT2033 and DRT2035

Specific log placement instructions for DRT2033/DRT2035 models.

Installing the DRT2040 and DRT2045 logs

Specific log placement instructions for DRT2040/DRT2045 models.

Installing and removing the glass door

Procedures for installing and removing the glass door.

Maintenance

Cleaning the glass door

How to clean the fireplace glass door safely and effectively.

MAINTENANCE SCHEDULE

Schedule for required annual and periodic maintenance tasks.

Accessory Components

Lighting Instructions

Millivolt Gas Valve

Step-by-step lighting instructions for millivolt gas valve systems.

Electronic Gas Valve

Step-by-step lighting instructions for electronic gas valve systems.

Troubleshooting

Replacement Parts

Warranty

Superior DRC2040 Specifications

General IconGeneral
BrandSuperior
ModelDRC2040
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals